Siemens SINUMERIK 840C Installation Instructions Manual page 561

Siemens computer drive installation instructions
Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
1636
Drive operating modes Emergency retraction
Default value
0
Input to select various operating modes in the drive operating modes word. It defines 8
operating modes for the following cases of failure:
Sign-of-life failure
DC-link voltage < MD 1633 or MD 1631
Activation of the autonomous drive emergency retraction through the NC
Table Drive operating modes Emergency retraction
Value input
0
Normal mode
1
Monitoring mode
2
Delayed regenerative braking
3
Delayed regenerative braking only with sign-of-life failure
4
Emergency retraction
5
Emergency retraction only with sign-of-life failure
6
Generator operation with possible return to normal mode
7
Generator operation without possible return to normal mode
This machine data is relevant only for Siemens-internal purposes and must
1637
Default value
0
Input of the time delay by which regenerative braking is delayed in the case of a failure.
This machine data is relevant only for Siemens-internal purposes and must
Input of the emergency retraction time, for which the emergency retraction speed (MD 1639) is
given as setpoint speed in the case of a failure.
7–146
Lower input limit
Upper input limit
0
Operating mode
not be altered.
Delay time regenerative braking
Lower input limit
Upper input limit
0
not be altered.
©
Siemens AG 1992 All Rights Reserved
Units
7
Units
10000
ms
6FC5197- AA50
SINUMERIK 840C (IA)
04.96
Active
at once
-
Active
at once