Parallel Connections Of Motor Modules; General; Minimum Motor Cable Lengths For Motors With Common Winding System - Siemens SINAMICS G130 Engineering Manual

Sinamics - low voltage sinamics drives
Hide thumbs Also See for SINAMICS G130:
Table of Contents

Advertisement

6.11 Parallel connections of Motor Modules

6.11.1

General

Motor Modules connected in parallel must always be identical in terms of type, voltage rating and power rating. If
SINAMICS S120 Motor Modules are connected in parallel, imbalances in current distribution can occur despite the current
compensation control. This means that a current derating factor of 5 % must be applied to parallel connections.
In the case of motors with a common winding system, it is important to observe the specified minimum cable lengths
between the Motor Modules and the motor in order to ensure that the parallel-connected Motor Modules are decoupled. If it
is not possible to realize cabling with the minimum required cable length, motor reactors or filters must be installed.
For detailed information on the subject of parallel converters, refer to section "Parallel connections of converters" in
chapter "Fundamental Principles and System Description".
6.11.2

Minimum motor cable lengths for motors with common winding system

The table below specifies the minimum required motor cable lengths for parallel connections of SINAMICS S120
Motor Modules in Chassis format with air cooling (frame sizes FX, GX, HX and JX) and with liquid cooling (frame
sizes FXL, GXL, HXL and JXL). The length specification refers to the distance between the output of each Motor
Module and the motor terminal box as measured along the motor cable.
Motor Module
P
at 400V
rated
Frame size
[kW]
Anschlussspannung DC 510 V bis 720 V
FX / FXL
110
FX / FXL
132
GX / GXL
160
GX
200
GX / GXL
250
HX / HXL
315
HX / HXL
400
HX / HXL
450
JX / JXL
560
JX / JXL
710
JX / JXL
800
JX / JXL
800
Motor Module
P
at 500V
rated
Frame size
[kW]
Anschlussspannung DC 675 V bis 900 V
FX
55
FX / FXL
55
FX
75
FX / FXL
90
GX
110
GX / GXL
132
GX
160
GX / GXL
200
HX
250
HX / HXL
315
HX / HXL
400
JX / HXL
500
HXL
560
JX / JXL
560
JX
630
JX / JXL
710
JX / JXL
900
JXL
1000
1)
permissible tolerance: –20 %
2)
These values apply to Motor Modules with line supply voltages of 500 V to 690 V 3AC (order number 6SL3x2x-1TGxx-xAA3).
Min. cable lengths for parallel connections of S120 Motor Modules connected to motors with a common winding system
Motor supply cable
1)
I
Minimum length
rated
[A]
[m]
210
30
260
27
310
20
380
17
490
15
605
13
745
10
840
9
985
8
1260
6
1330
5
1405
5
Motor supply cable Motor Module
1)
I
Minimum length
rated
[A]
[m]
2)
85
80
100
72
120
65
150
55
175
50
215
40
260
32
330
25
410
20
465
18
575
15
735
13
810
13
810
11
910
10
1025
8.5
1270
7
1560
6
SINAMICS Engineering Manual – November 2015
Engineering Information
P
at 690V
Frame size
rated
[kW]
Anschlussspannung DC 890 V bis 1035 V
FX
75
FX / FXL
90
FX
110
FX / FXL
132
GX
160
GX / GXL
200
GX
250
GX / GXL
315
HX
400
HX / HXL
450
HX / HXL
560
JX / HXL
710
HXL
800
JX / JXL
800
JX
900
JX / JXL
1000
JX / JXL
1200
JXL
1500
SINAMICS S120
Motor supply cable
I
Minimum length
rated
[A]
[m]
2)
85
100
100
90
120
80
150
70
175
60
215
50
260
40
330
30
410
25
465
25
575
20
735
18
810
18
810
15
910
12
1025
10
1270
8
1560
7
381/528
Ó Siemens AG
1)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g150Sinamics s120Sinamics s150

Table of Contents