Connection

6.8 Connection of RS485 serial interface

6.8
Connection of RS485 serial interface
The following devices can be connected to the serial interface:
● Siebert display type S102 (connections: see chapter Connection of Siebert display via
RS485 (Page 39))
● Operator Panels or other HMI devices with RS485 and Modbus protocol RTU
● Communication partner with Modbus protocol RTU
Table 6- 6
Labeling
EIA-485 T+
EIA-485 T-
EIA-485 D+'
EIA-485 D-'
EIA-485 D+
EIA-485 D-
If a SIWAREX WP231 module forms the termination of an RS485 network, insert wire
jumpers between the D+' and T+ terminals and between the D-' and T- terminals for
termination of the bus network.
38
Connection of RS485 serial interface
Function
RS485 termination +
RS485 termination -
RS485 data line +' for looping through of bus signal
RS485 data line -' for looping through of bus signal
RS485 data line + for feeding in of bus signal
RS485 data line - for feeding in of bus signal