Error Codes Of Function Block - Siemens SIWAREX WP231 Manual

Hide thumbs Also See for SIWAREX WP231:
Table of Contents

Advertisement

Communication
11.1 Integration in SIMATIC S7-1200
11.1.6

Error codes of function block

Table 11- 3
Statuses/errors when working with the function block
Error bit
bo_ApplIDError
bo_ApplIDDRError
bo_SFBError
bo_RdPerError
bo_LifeBitError
bo_StartUpError
bo_WrongFW
bo_InvalidCMD
bo_DataOperationError
bo_StartUp
Note
If execution of the function block is faulty, the variables shown do not correspond to the
actual status in the module.
152
Error description
Address module does not match the function block
Data record does not match the inserted module
Runtime error during transmission of data record
Reading of I/O data failed
SIWAREX no longer responds
Command was sent although StartUp is still TRUE
Data record version does not match the firmware
An invalid command code was sent
Synchronous data operation error has occurred
Startup synchronization of module running
SIWAREX WP231
Manual, 07/2014, A5E31238908A-02

Advertisement

Table of Contents
loading

Table of Contents