Dr 46 Protocol Contents; Overview - Siemens SIWAREX WP231 Manual

Hide thumbs Also See for SIWAREX WP231:
Table of Contents

Advertisement

Scale parameters and functions

8.24 DR 46 protocol contents

8.24
DR 46 protocol contents
8.24.1

Overview

Protocol data is provided in data record DR 46.
Table 8- 25
Assignment of data record 46
Variable
Note
Data record number
Contains no. of data record
Length
Data record length information
Application
Information about which appli-
cation the DR belongs to
Version identifier
Information about current data
record version
Oldest protocol ID
Oldest protocol ID, 0: No entry
available
Newest protocol ID
ID of last saved protocol entry,
0: No entry available
Selected protocol ID,
ID of subsequent protocol entry,
numeric
0: No entry available)
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
String header for
String header
report ID currently
selected
Gross/net identifier
Gross/net identifier
Delimiters
Delimiter (semicolon)
G/N weight
G/N weight
Delimiters
Delimiter (semicolon)
Unit of weight
Unit of weight
Delimiters
Delimiter (semicolon)
Tare identifier
Tare identifier
No entry: Scale was not tared
when logging
T: Scale was tared with manual
tare when logging
pT: Scale was tared with tare
specification from DR15 when
logging
126
Type
Length
Rw
(bytes)
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
r
ULONG
4
r
ULONG
4
r
ULONG
4
r
UBYTE[2]
2
r
CHAR[12]
12
r
UBYTE[2]
2
r
CHAR[12]
12
r
UBYTE[2]
2
r
CHAR[12]
12
r
UBYTE[2]
2
r
CHAR[2]
2
r
CHAR
1
r
CHAR[8]
8
r
CHAR
1
r
CHAR[4]
4
r
CHAR
1
r
CHAR[2]
2
r
Default
Min.
Max.
46
128
101
1
1
65635
0
1
4,294,967,295
0
1
4,294,967,295
0
1
4,294,967,295
12.12
"
0"
"
"4294967295"
1"
12.12
"
0"
"
"4294967295"
1"
12.12
"
0"
"
" 4294967295" 6125
1"
28.28
" "
";"
"
"
";"
"
"
";"
" "
Manual, 07/2014, A5E31238908A-02
Modbus
registers
6100
6101
6102
6103
6104
6106
6108
6110
6111
6117
6118
6124
6131
6132*
1)
SIWAREX WP231