Parameterization
For a standard configuration with correct pre-assignment of the temperature channels, the
Terminal Module TM120 must be located between the Sensor Module and the Motor Module
(DRIVE-CLiQ).
If this is not the case, you must parameterize all of the required temperature channels in both
the Motor Module and Terminal Module TM120.
You must always carefully check the temperature shutdown circuits (e.g. by disconnecting
the sensors) before commissioning the motor for the first time.
Use the expert list to parameterize the drive.
Table 3- 13
Parameterization in the drive:
Parameter
Input
p0600
Motor temperature sensor for monitoring
20: Temperature sensor via BICO interconnection p0608
p0601
Motor temperature sensor, sensor type
11: Evaluation via several temperature channels BICO
p0606
Motor temperature timer
0...2 s
Sets the timer for the alarm threshold for the motor temperature monitoring, if alarm with timer was
selected in p4610...4613.
This timer is started when the temperature alarm threshold (p0604) is exceeded.
If the timer expires before the temperature falls below the alarm threshold, then fault F07011 is out-
put.
p0608
[0...3] CI: Motor temperature, signal source 2
Sets the signal source 2 for the evaluation of the motor temperature via a BICO interconnection, e.g.
[0]: Motor temperature channel 1 TM120 . r4105[0]
[1]: Motor temperature channel 2 TM120 . r4105[1]
[2]: Motor temperature channel 3 TM120 . r4105[2]
[3]: Motor temperature channel 4 TM120 . r4105[3]
p4610...p4613
Motor temperature sensor 1...4 sensor type
Sets the temperature sensor type for the motor temperature monitoring. The following values are
possible for linear motors:
0: No sensor
10: PTC fault
12: PTC alarm & timer
20: KTY84, PT100, PT1000
30: Bimetallic NC contact fault
32: Bimetallic NC contact alarm & timer
If you make a selection with timer, you must pre-assign parameter p0606 with the corresponding
timer for a maximum of 2 s.
STARTER Commissioning Manual
Commissioning Manual, (IH1), 07/2016, 6SL3097-4AF00-0BP5
3.13 Commissioning of SIMOTICS L-1FN3 linear motors
Commissioning
203