CHAPTER 5: SETTINGS
— This setting specifies the time delay for automatic reset of the pushbutton when in "Latched"
PUSHBTN 1 AUTORST DELAY
mode.
— This setting assigns the FlexLogic operand serving to inhibit user-programmable pushbutton
PUSHBTN 1 REMOTE
operation from the operand assigned to the
— This setting assigns the FlexLogic operand serving to inhibit user-programmable pushbutton operation
PUSHBTN 1 LOCAL
from the front panel pushbuttons. This inhibit functionality is not applicable to pushbutton autoreset.
— This setting applies only to "Self-Reset" mode and specifies the duration of the user-
PUSHBTN 1 DROP-OUT TIME
programmable pushbutton active status after the front panel pushbutton has been released. When activated remotely,
this setting specifies the entire activation time of the pushbutton; the length of time the operand selected by
remains on has no effect on the pulse duration.
— This setting assigns the FlexLogic operand serving to drive the front panel pushbutton LED. If this
PUSHBTN 1 LED CTL
setting is "Off," then LED operation is directly linked to the
— This setting controls the behavior of the user-programmable pushbutton on message that is
PUSHBTN 1 MESSAGE
programmed in the
PUSHBTN 1 ID
off message that is programmed in the
When set to "Disabled", user-programmable pushbutton messages do not display. Otherwise the on message displays
when the user-programmable pushbutton becomes activated, and if in the "Latched" mode the off message displays when
the user-programmable pushbutton becomes deactivated.
When set to "Normal", the duration the message displays is as specified by the
When set to "High Priority", the duration of the off message is as specified by the
message is displayed as long as the user-programmable pushbutton is activated. While activated, target and other
messages are suppressed. To allow front panel keypad operation, when a keypad button is pressed the message is
supressed for 10 seconds.
— If this setting is enabled, each user-programmable pushbutton state change is logged as an
PUSHBUTTON 1 EVENTS
event into the event recorder.
The figures show the user-programmable pushbutton logic.
L90 LINE CURRENT DIFFERENTIAL SYSTEM – INSTRUCTION MANUAL
or
PUSHBTN 1 SET
PUSHBTN 1 RESET
PUSHBUTTON 1 ON
and
settings, and the behavior of the user-programmable pushbutton
PUSHBTN 1 ON TEXT
and
PUSHBTN 1 ID
PUSHBTN 1 OFF TEXT
settings.
operand.
settings.
setting.
FLASH MESSAGE TIME
setting, but the on
FLASH MESSAGE TIME
PRODUCT SETUP