Desig.
ACS560
Main cir-
cuit nomin-
al I
, I
1N
N
W
03A3-4
42
04A0-4
50
05A6-4
68
07A2-4
88
09A4-4
115
12A6-4
158
017A-4
208
025A-4
322
033A-4
405
039A-4
500
046A-4
594
062A-4
810
073A-4
999
088A-4
1215
106A-4
1485
145A-4
1440
169A-4
1940
206A-4
2310
246A-4
3300
293A-4
3900

Terminal and lead-through data for the power cables

Input, motor, resistor and DC cable lead-throughs, maximum wire sizes (per phase) and
terminal screw sizes and tightening torques (T) are given below.
Desig.
Fra
ACS560
me
min. ( single core
size
and / multicore)
2
mm
3 phases U
= 400V (380...480V)
N
02A6-4
R0
0.2/0.2
03A3-4
R0
0.2/0.2
04A0-4
R0
0.2/0.2
Thermal losses
Control cir-
Control cir-
cuit Min.
cuit Max.
load
load
W
W
0.3
9
0.3
9
0.3
9
0.3
9
0.3
9
0.3
9
0.3
9
0.3
9
3.5
25
3.5
25
3.5
25
3.5
25
3.5
25
3.5
25
3.5
25
4.1
36
4.1
36
4.1
36
4.1
36
4.1
36
U1. V1. W1 / U2. V2. W2 / R+. R- / DC+. DC- terminal
Max.( (single core and/
multi-core )
2
AWG
mm
18
6/6
18
6/6
18
6/6
Air flow
Main circuit
and control
circuit Max.
load
3
W
m
/h
51
57
59
57
77
57
97
57
124
57
167
63
217
128
331
128
430
TBA
525
TBA
619
TBA
835
280
1024
280
1240
280
1510
435
1476
435
1976
450
2346
550
3336
550
3936
1150
torque
AWG
N·m
8
0.5...0.6
8
0.5...0.6
8
0.5...0.6
Technical data 117
Noise
Frame size
dB(A)
63.10
R0
63.10
R0
63.10
R0
63.10
R0
63.10
R0
58.80
R1
65.80
R2
65.80
R2
TBA
R3
TBA
R3
TBA
R3
62
R4
62
R4
62
R5
67
R5
67
R6
67
R7
67
R7
65
R8
65
R8
PE terminals
max
torque
2
lbf·ft
mm
N·m
0.4
6
1.2
0.4
6
1.2
0.4
6
1.2