The parameters in the ALARM SETUP menu are defined and programmed as follows:
ALARM DWELL: The alarm will be held for monitor display (full video on monitor B, when applicable) and
recording for the programmed duration (3 to 60 seconds). Individual alarms will be recorded for the programmed
ALARM DWELL time or until the alarm is cleared. If two or more alarms are active at the same time, video is
alternately recorded until the dwell time expires or the alarm conditions are cleared.
NOTE: If Alarm Dwell is set to FOLLOWS, alarms will follow the alarm input.These alarms cannot be cleared
until the alarm contact is reset.
ALARM LIST:The ALARM LIST defines which alarm inputs are enabled and will follow programming as
established in the VCR OUT option if applicable. Alarming camera numbers are selected by pressing the
corresponding camera # key on the front panel or keyboard.
NOTE: For 6-channel models only (LTC 2622/90).
ALARM DISPLAY: Alarm display is available for MON A and MON B. Alarm display MON A settings will allow
customized alarm viewing and camera pre-position showing. MON B will show full screen on alarm and at 2 second
intervals when multiple alarms are activated.
ALARM INPUT:The Alarm Input menu sets the type of input to Normally Open or Normally Closed for an
individual alarm input.
BEEPER:The LTC 2600 Series provides an audible alarm. If the beeper is enabled, the beeper will sound for the
duration of the alarm. Press any key to turn the beeper off once it has sounded. Setting the beeper to disable will
prevent the beeper from sounding.
NOTE:The multiplexer has one alarm output relay. This relay can be programmed to switch ON for alarms.
7.
Return to the ADVANCED SETUP menu. Select the CAMERA TITLES option. Each camera can be
designated with a 16-character name, if desired. The factory-set default name for each camera is simply a
numerical designation (e.g. camera 01).