09.95
10.4.3
10.4.3.1
Prerequisites
•
All axis setpoint cables inserted.
•
Control direction correct.
•
Position control loops closed.
•
All gain values correct.
•
Safety signals active (EMERGENCY STOP, HARDWARE LIMIT SWITCH).
The following alarms can prevent axis traversing:
Alarm No.
The following additional signals (which do not trigger an alarm) are required for traversing in
jog mode:
No feed disable
No feed disable all
No axis disable
Servo enable
No follow-up mode
No parking axis
Pulse enable with
digital drive
© Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
More user manuals on
Axis traversing
Traversing in jog mode
2000
"EMERGENCY STOP"
148*
Software limit switch approached (triggered by MD224*, 228*, 232*, 236*)
152*
Software limit switch approached (triggered by MD224*, 228*, 232*, 236*)
188*
Hardware limit switch approached
192*
Hardware limit switch approached
168*
Interface unit revoked servo enable for traversing axis
156*
Set speed too high. Triggered by NC MD 264*.
112*
Zero-speed monitor
Axis is not in position. Triggered by NC MD 372*
116*
Contour monitor (triggered by NC MD 332*, 336*)
132*
Hardware measuring-circuit monitor
136*
Measuring system dirty
ManualsBase.com
Description
X, Y, Z, 4 - 9
X, Y, Z, 4 - 9
Interface test
X, Y, Z, 4 - 9
X, Y, Z, 4 - 9
X, Y, Z, 4 - 9
6FC5197- AA50
10 Axis and Spindle Installation
10.4.3 Axis traversing
10–33