07.97
6.10
60000
With the introduction of this MD it is no longer necessary to define the UMS size in the
configuration file in the MMC master control.
The upper input limit depends on the NCK memory capacity (4 or 8 MB memory).
Zero means no UMS (see functional description of "Flexible memory configuration").
60001
The upper input limit depends on the NCK memory capacity (4 or 8 MB memory).
60002
Zero means no IKA points.
60003
If an area of the memory is reserved for MSD drive software, 194 KB memory is occupied.
Zero means no memory.
The memory is only required for digital drives. The software only loads the MSD software if the
memory has been reserved for it.
Note:
The meaning of this machine data changes as from SW 6.
_______
1)
As from SW 4
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
More user manuals on

MDs for flexible memory configuration

Default value
Lower input limit
256 KB
Size of part program memory
Default value
Lower input limit
704 KB
Default value
Lower input limit
4 000
Memory for drive software MSD
Default value
Lower input limit
0
ManualsBase.com
6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.10 MDs for flexible memory configuration
1)
Size of UMS memory
Upper input limit
960 or 2 760 KB
0
2 760 KB (as from
SW 4.4)
Upper input limit
960 or 2 760 KB
8
4 920 KB (as from
SW 4.4)
1)
Number of IKA points
Upper input limit
0
65 535
0
Upper input limit
0
1
6FC5197- AA50
Active
after SK
"Reconfigure
memory"
Units
4 KB/8 KB
Active
after SK
1)
"Reconfigure
memory"
Units
4 KB
Active
after SK
"Reconfigure
memory"
Units
1 IKA point
Active
after SK
1)
"Reconfigure
memory"
Units
6–211