7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
Case 1
MD 1403 = 0
Case 2
MD 1403 = X
1404
Default value
100.0/5 000.0
Input of timer for pulse suppression by drive. In the event of a fault (in generator braking mode
or with controller disabled), the control pulses for the power section transistors are suppressed
on the drive side after expiry of the time set in the adjustable timer. The pulses are
suppressed beforehand if the speed drops below the threshold set in machine data "Creep
speed pulse suppression" (MD 1403) before the timer expires. Monitoring takes place
sequentially on the drive and servo sides with variously adjustable timers. The default setting is
dependent on the motor type (FDD ˆ =100, MSD ˆ =5000) and is parameterized by the drive
configuration during start-up.
Note:
Under normal circumstances, shutdown is implemented sequentially on the drive and servo
sides, with variously adjustable timers (NC MD 156, NC MD 12240) and, in the event of a
fault, only on the drive side with timer MD 1404.
7–116
More user manuals on
Controller enable
n
I
n
I
Timer pulse suppression
Lower input value
0.0
ManualsBase.com
t
t
Motor coasts out
t
Upper input value
100 000.0
©
Siemens AG 1992 All Rights Reserved
09.95
Active
at once
Units
ms
6FC5197- AA50
SINUMERIK 840C (IA)