D.9

Identifying the Primary System Power Requirement

Procedure
Proceed as follows to identify the primary power requirement of a system:
1.
Determine overall secondary power requirement
power requirements of the boards/components used
+
power requirement of connected workpoint clients (analog and digital telephones),
key modules and adapters
=
overall secondary power requirement
2.
Identifying primary power requirement
overall secondary power requirement
+
requirements of power supply units (UPSM = 30 W, PSUP/UPSC-D/UPSC-DR =
12 W respectively)
+
requirements of EPSU2/EPSU2R (10 W respectively)
=
the result should be multiplied by the factor 1.2 to allow for the degree of efficiency of
the power supply.