Mitsubishi Electric FX3G SERIES Programming Manual page 477

Programmable controllers
Hide thumbs Also See for FX3G SERIES:
Table of Contents

Advertisement

FX
/FX
/FX
Series Programmable Controllers
3G
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
Related devices
Device
*1
ch1
ch0
ch2
M8371
M8401
M8421 Sending wait flag
M8372
M8402
M8422 Sending request
M8373
M8403
M8423 Receiving complete flag
M8404
M8424 Carrier detection flag
M8405
M8425 Data Set Ready (DSR) Flag
M8379
M8409
M8429 Time-out check flag
M8062
M8063
M8438 Serial communication error
*1.
Ch2 is not available in 14-point and 24-point type FX
Ch0 is available only in FX
*2.
Cleared when the PLC mode is changed from RUN to STOP.
*3.
Available in all FX
*4.
Cleared when PLC power supply is turned from OFF to ON.
System configuration
For using this instruction, it is necessary to attach one of the products shown in the table below to the main unit.
PLC
FX
,
3U
FX
-32MT-LT(-2)
3UC
FX
(D,DS,DSS)
3UC
FX
3G
*1.
Required to use ch0 (standard built-in RS-422 port) in FX
Differences between the RS (FNC 80) instruction and RS2 (FNC 87) instruction
Item
Header size
1 to 4 characters (bytes)
Terminator size
1 to 4 characters (bytes)
Attachment of
The check sum can be
check sum
automatically attached.
Used channel
ch0, ch1, ch2
number
→ For detailed explanation, refer to the Data Communication Edition.
Name
*1
*2
*2
*2
*4
PLCs.
3G
PLCs and FX
/FX
3G
3U
3UC
→ For the system configuration, refer to the respective PLC Hardware Edition manual.
→ For detailed explanation, refer to the Data Communication Edition manual.
Communication type
RS-232C communication
FX
RS-485 communication
FX
RS-232C communication
FX
RS-485 communication
FX
FX
RS-232C communication
RS-232C/RS-422 converter
(FX-232AW, FX232AWC and FX-232AWC-H)
RS-485 communication
FX
RS2 instruction
RS instruction
Up to 1 character (byte)
Up to 1 character (byte)
The check sum should be
attached by a user
program.
ch1
16 External FX Device – FNC 80 to FNC 89
16.8 FNC 87 – RS2 / Serial Communication 2
Device
*1
ch1
ch0
ch2
D8370
D8400 D8420 Communication format setting
D8372
D8402 D8422
D8373
D8403 D8423 Monitor for number of received data
*3
D8405 D8425 Communication parameter display
D8379
D8409 D8429 Time-out time setting
D8380
D8410 D8430 Header 1, 2
D8381
D8411 D8431 Header 3, 4
D8382
D8412 D8432 Terminator 1, 2
D8383
D8413 D8433 Terminator 3, 4
D8384
D8414 D8434 Receiving sum (received data)
D8385
D8415 D8435 Receiving sum (calculation result)
D8386
D8416 D8436 Sending sum
D8389
D8419 D8439 Operation mode display
D8062
D8063 D8438 Serial communication error code
PLCs.
3G
PLCs Ver. 2.30 or later.
-232-BD or FX
-232ADP(-MB)
3U
3U
-485-BD or FX
-485ADP(-MB)
3U
3U
-232ADP(-MB)
3U
-485ADP(-MB)
3U
-232BD or FX
-232ADP(-MB) (which requires FX
3G
3U
*1
-485-BD or FX
-485ADP(-MB) (which requires FX
3G
3U
PLCs.
3G
For the RS2 instruction, up to 4 characters (bytes) can be
specified as a header or terminator.
For the RS2 instruction, the check sum can be
automatically attached to the sent and received data.
In this case, however, make sure to use a terminator in the
communication frame to be sent and received.
For the RS2 instruction:
Ch2 is not available in 14-point and 24-point type FX
PLCs.
Ch0 is available only in FX
Name
*1
Remaining number of data to be
*2
sent
Option
-CNV-ADP)
3G
-CNV-ADP)
3G
Remarks
PLCs.
3G
11
12
*2
13
14
*4
15
16
17
18
19
3G
20
475