8.3.4 Standby Mode
This is the standby mode before converting to operation mode (PV Auto, PV Only, Battery
discharge mode). Conversion to the operation mode (PV Auto, PV Only, Battery discharge
mode) is made by the EMS decision.
8.3.5 Forced-Charge Mode (Maintenance mode)
In this mode, solar energy generation is not used, but the power continuously flows from the
electric power system to the battery.
[Figure 8-11: Indication screen on Forced charged Mode]
8.3.6 Stand-Alone Mode
When the All In One is disconnected from the energy meter, or the power conversion system
is disconnected from the energy management system (EMS), the All In One system enters
into the Stand-Alone Mode. The system operates in a PV- only mode.
Australia (Eng.) 05/2015. Rev1.1
[Figure 8-10: Indication screen on Standby Mode]
[Figure 8-12: Indication screen on stand-alone mode]
8. Operation Test
63