Basic Specifications; Grounding The Pv Inverter - Samsung ELSR362-00004 Installation Manual

Res 3.6 kwh all in one
Hide thumbs Also See for ELSR362-00004:
Table of Contents

Advertisement

2. Safety

2.3.1 Basic Specifications

Max. input total power
Max. input power per string
Max. input voltage
Min. input voltage/Initial input voltage
MPPT voltage range
Max. input current per string
Number of independent MPP trackers
Battery nominal capacity/usable capacity
DOD(Depth of Discharge)/Range
Battery voltage range/nominal voltage
Battery Max. current
Battery DC/DC Converter Data
Rated Power
Technology
Rated power
Max. apparent AC power
Max. current
Max. allowed current for fuse protection
Nominal AC voltage/range
Rated power frequency

2.3.2 Grounding the PV Inverter

The PV inverter complies with the local requirements for grounding the PV inverter.
Samsung SDI recommends connecting and grounding the PV inverter
electricity conducting surfaces in such a way that there is continuous conduction in order to
achieve maximum protection for systems and persons. And the PV inverter
and DC (-) pole are not permitted to be grounded.
8
PV Generator Data (DC)
Battery Data (DC)
Grid Connection Data (AC)
[Table 2-2: Basic Specifications]
6.6 kWp
3.3 kWp
550 V
125 V/150 V
125 V~500 V
15 A
2
3.6 kWh/3.24kWh
90% (5~95%)
48.0 V~65.9 V/60 V
46.3 A
2.0 kW
Isolated
4.6 kW
5 kVA
20 A
32 A
230 V/184 V~264 V
50 Hz
s frame and other
'
s DC (+) pole
'
Australia (Eng.) 05/2015. Rev1.1