ALARM SETUP

Setting
1
1
Press the MENU button, then press the O button to select "3. ALARM SET".
2
Press the MENU button.
3
Press the + (or –) button to select the desired setting for "BUZZER", then press the O button.
Following the same procedure, select the desired settings for "DURATION", "RETRIGGER", "MONITOR1
ZOOM", "MONITOR1 STILL", "MONITOR2 OUT", "VIDEO LOSS".
(For more information on each setting, please refer to "Alarm Settings" below.)
4
Press the MENU button, then press the O button to select "7. ENTER" and press the MENU button again.
Alarm Settings
BUZZER
ON: The buzzer will sound when there is an alarm trigger.
OFF: The buzzer will not sound.
DURATION
10SEC, 20SEC, 30SEC, 40SEC, 50SEC, 60SEC: Duration of
the alarm.
CC: The alarm will go on as long as the alarm signal is
received (minimum 10 second).
RETRIGGER
ON: If a second alarm trigger is received during the alarm
operations for that same alarm number, then it will also
be received.
OFF: During the alarm operations for an alarm number, any
alarm trigger at the same alarm number will be ignored.
MONITOR1 ZOOM
ON: When an alarm trigger is received, the image displayed
on monitor 1 will be zoomed in.
If the alarm trigger was recorded on tape, the zoom
function will not operate.
OFF:
The zoom function will not operate.
2
3
MONITOR1 STILL
ON: When an alarm trigger is received, the image displayed
on monitor 1 will be freezed.
If the alarm trigger was recorded on tape, the still
function will not operate.
OFF: The still function will not operate.
MONITOR2 OUT
ON: When an alarm trigger is received, the image from the
camera corresponding to the alarm trigger is displayed
on monitor 2.
When 2 or more alarm triggers are received
simultaneously, monitor 2 will display sequentially all
the images from the cameras corresponding to the
alarm triggers.
OFF: The monitor 2 output function will not operate.
VIDEO LOSS
ON: An alarm is generated if there is loss of the video signal.
The display on monitor 1 will automatically switch to 16
divisions split screen, "A" will be displayed for the
camera where the loss of video signal occurred and the
ALARM DURATION will be 30 seconds. This alarm will
not be included in the ALARM DATA display.
OFF: An alarm is not generated if there is loss of the video signal.