Constant Airflow Settings
WARNING:
Isolate electricity supply
before removing or
replacing jumper switch.
•
Remove jumper switch if
10 L/S constant airflow rate
is required.
•
Replace jumper switch if
5 L/S constant airflow rate
is required.*
* Factory set at 5 L/S.
To Clean or Service Fan
WARNING:
Always isolate fan from mains supply
before cleaning.
Do not use solvents to clean this fan.
•
Loosen the two retaining screws under
grille (Do not remove screws), then
pull bottom of grille while lifting.
•
The fan may now be cleaned using a
brush, cotton bud or damp cloth.
DO NOT IMMERSE IN WATER.
•
Keep points 1 (sensor) and 2
(impeller) clean for best performance.
•
After cleaning replace Internal Grille .
This Greenwood product CV100 is guaranteed for a period of 2 years from the date of purchase of the Product against fault in manufacture. In case of such fault in manufacture
apparent during the Guarantee Period, Greenwood may, at its absolute discretion, repair the product, replace the product free of charge or refund the cost of the product AS LONG AS
AND ONLY IF:
1.
The Product is returned to Greenwood within the Guarantee Period with evidence of purchase date:
2.
The Product has not been misused or handled carelessly or used on an inappropriate voltage supply;
3.
Repairs have not been attempted other than by Greenwood's service staff or authorised dealers; and
4.
In Greenwood's sole discretion, the Product is found to be faulty. If it were not found to be faulty, the Product would be available for collection from the relevant
Greenwoods premises within one calendar month and if it was not collected, it would be subsequently delivered by Greenwood and a delivery charge will be made.
(the guarantee)
This guarantee does not confer any rights other than those expressly set out above and does not cover any claims for consequential
loss, damage or any costs incurred in the replacement of the faulty Product. This Guarantee is offered as an extra benefit and
does not affect your statutory right as a consumer.
For further information contact the Greenwood Customer Services Department
Greenwood Air Management Ltd
Greenwood House, Brookside Avenue, Rustington, West Sussex BN16 3LF
Tel: 01903 771021 Fax: 01903 782398
Email: info@greenwood.co.uk www.greenwood.co.uk
4
The Guarantee Period
05.10.753 GW64100140G Issue 1 October 2006
INSTALLATION INSTRUCTIONS
Constant Volume Single Point Extract Fan
Greenwoods Unity CV100 is a continuously
running extract fan, designed to offer a
simplistic approach to the Building
Regulations and an energy efficient domestic
ventilation solution. The design concept
revolves around 'one product', which has been
designed to be flexible in application and to
EC Declaration of Conformity
We Declare that Type CV100
Fan conforms to 89/336/EEC
73/23/EEC
Unity CV100
meet the performance requirements of all wet
rooms within a dwelling (to be configured
during installation). Offering varying
installations including through wall, ceiling
and inline options, the Unity fan is also silent
in operation and is supplied with an
aesthetically styled internal grille.
READ ALL INSTRUCTIONS
BEFORE COMMENCING
INSTALLATIONS
•
Observe appropriate safety precautions if
working on steps or ladders. Wear eye
protection when breaking out wall or window
materials etc.
•
The fans should not be sited where it would
be subject to a direct source of heat in
excess of 40ºC.
•
When installing wall mounted fans, ensure
that there are no buried cables or pipes in
the way. It is recommended that this fan is
mounted 1.8m above floor level.
•
A clearance of 75mm to be allowed on at
least one side of the fan for the removal of
the internal grille.
Need help?
Do you have a question about the Unity CV100 and is the answer not in the manual?
Questions and answers