Siemens RDH10RF User Manual

Siemens RDH10RF User Manual

Wireless room temperature controller with large lcd non-programmable, for heating or cooling systems
Hide thumbs Also See for RDH10RF:

Advertisement

Installation Instructions for the Siemens RF
1
4
Wiring Diagram
Legend
LX
L1
L2
Terminals
L
N
2
5
Item to be controlled
= Common
= Live feed to
item to be
controlled
= Changeover
contact
= Live
= Neutral
Technical Helpline: 0870 850 0184
s
3
6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RDH10RF and is the answer not in the manual?

Questions and answers

Peter Draper
February 9, 2025

i have changed battery but stat is not working properly

1 comments:
Mr. Anderson
February 11, 2025

The Siemens RDH10RF thermostat may not be working properly after changing the battery due to one or more of the following reasons:

1. Factory Reset: If the RESET button was accidentally pressed during battery replacement, the thermostat may have returned to factory settings, requiring reconfiguration.
2. Low Battery Power: If the new batteries are not fully charged or are not AA alkaline batteries as required, the thermostat may not function correctly.
3. Incorrect Battery Installation: The batteries might be inserted incorrectly, preventing proper operation.
4. Loss of Connection: If the thermostat is wireless (RF model), it may have lost communication with the receiver and needs to be re-paired.
5. Internal Memory Loss: Removing the batteries may have erased stored settings, requiring the thermostat to be set up again.

To resolve the issue, ensure the correct battery type and polarity, check for a communication reset if applicable, and reconfigure the thermostat settings if needed.

This answer is automatically generated

Summary of Contents for Siemens RDH10RF

  • Page 1 Installation Instructions for the Siemens RF receiver Wiring Diagram Item to be controlled Legend = Common = Live feed to item to be controlled = Changeover contact Terminals = Live = Neutral Technical Helpline: 0870 850 0184...
  • Page 2 Note: The transmitter and receiver are supplied in a single box already configured. This Configuration Instructions for the Siemens RF units procedure only needs to be followed in case of communication issues Press and release SET button, this Press and release LEARN button...
  • Page 3 SIEMENS RDH/RDJ- RF/RECEIVER. RCR10/433 VOLT NOTE, LX, L1 & L2 ARE ‘VOLTS FREE’ CONTACTS. BOILER TERMINAL BLOCK REMOVE LINK - Marked (TO EXTERNALCONTROLS) & CONNECT AS SHOWN...
  • Page 4 SIEMENS RDH/RDJ- RF/RECEIVER. RCR10/433 VOLT WIRE LINK L - LX 230 VOLT, SWITCH LIVE TO BOILER OR VALVE NOTE, LX, L1 & L2 ARE VOLTS FREE CONTACTS. TO SWITCH, 230VOLT MAINS LIVE ON L1, PUT LINK BETWEEN L & LX...
  • Page 5 How to use your Siemens RDH10/RDH10RF This leaflet gives you easy to follow instructions on how to use your RDH10 digital room thermostat. Digital Room Thermostat How do I set the required temperature? Turn the rotary dial to the left to decrease the required temperature, or to the right to increase the required temperature.
  • Page 6 Non-programmable, for heating or cooling systems • Large LCD • Battery-powered: 2 x alkaline type AA batteries, 1.5 V • RCR10/433 receiver The RDH10RF is used to control the room temperature in heating or cooling systems. Typical applications: • Homes • Residential buildings •...
  • Page 7 Switching differential Room temperature setpoint Output signal for cooling T[°C] The RDH10RF provides room temperature control only. Temperature sensor The digital display shows the actual room temperature and the comfort temperature Display setpoint. When the heating output is active, the triangle symbol appears.
  • Page 8 Display of the room temperature in °C Indicates a request for heat Temperature setting knob Battery compartment Comfort temperature setpoint Indicates RF signal test TEST Indicates low battery power; replace batteries 3/10 Siemens Room temperature controllers CE1N3070en Building Technologies 20.11.2007...
  • Page 9 Mounting height is about 1.5 m above the floor. The unit can be fitted to a recessed conduit box. 4/10 Siemens Room temperature controllers CE1N3070en Building Technologies...
  • Page 10 Transport IEC 721-3-2 Climatic conditions Class 2K3 Temperature -25…+60 °C Humidity <95% r.h. Mechanical conditions Class 2M2 Storage IEC 721-3-1 Climatic conditions Class 1K3 Temperature -10…+60 °C Humidity <90% r. h. 5/10 Siemens Room temperature controllers CE1N3070en Building Technologies 20.11.2007...
  • Page 11 EN 301489-3 V1.4.1 Safety class III as per EN 60950-1 Pollution degree Degree of protection of housing IP20 Weight (incl. package) General RDH10RF/SET 515 g Color of housing front Signal-white RAL 9003 Housing material ABS (LCD lens: PC) Receiver RCR10/433 Operating voltage AC 230 V +10/ −...
  • Page 12 Live, AC 24…250 V N.O. contact, AC 24…250 V / 8 (3) A N.C. contact, AC 24…250 V / 8 (3) A Circulating pump Neutral conductor Neutral conductor Receiver RCR10/433 Actuating device 8(3) 7/10 Siemens Room temperature controllers CE1N3070en Building Technologies 20.11.2007...
  • Page 13 (precontrol by manual mixing valve) Thermal reset limit thermostat Cooling equipment Safety limit thermostat Room temperature controller RDH10RF Circulating pump Receiver RCR10/433 3-port valve with manual adjustment Magnetic valve 8/10...
  • Page 14 Dimensions Room temperature controller Baseplate 9/10 Siemens Room temperature controllers CE1N3070en Building Technologies 20.11.2007...
  • Page 15 With fold-out stand Receiver © 10/10 2007 Siemens Switzerland Ltd Subject to change Siemens Room temperature controllers CE1N3070en Building Technologies 20.11.2007...

This manual is also suitable for:

Rdh10 setRdh100

Table of Contents