The Siemens RDH10RF/SET thermostat may not be detecting the boiler due to the following potential reasons:
1. Improper Pairing: The RDH10RF thermostat and the RCR10/433 receiver may not be properly paired. Ensure that the pairing process has been completed correctly using the "Learn" button on the receiver.
2. Electrical Connection Issues: Check the electrical connections of the receiver to ensure they comply with local regulations and are securely connected.
3. Power Supply Problems: Verify that the receiver is receiving the correct operating voltage (AC 230 V ±10/−15%) and that it is functioning properly.
4. Interference or Range Issues: The radio signal between the thermostat and the receiver may be obstructed or out of range. Ensure that the devices are within the recommended range and free from interference.
5. Battery Level: If the thermostat uses batteries, ensure they are properly installed and have sufficient charge, as low batteries can affect performance.
6. Reset Required: If issues persist, try resetting the receiver by pressing the "Test" and "Learn" buttons together. Re-pair the devices after the reset.
If these steps do not resolve the issue, further troubleshooting may be necessary.
Self-learning room temperature controller (21 pages)
Summary of Contents for Siemens RDH10RF/SET
Page 1
RDH10RF RCR10/433 Wireless room temperature controller with LCD RDH10RF/SET Non-programmable, for heating or cooling systems • Operating modes: Automatic, Comfort, Energy Saving, and Frost Protection • LCD-Display 50 x 45 (W x H) • RDH10RF transmitter, battery-powered • RCR10/433 receiver, mains powered •...
Backup exchanging batteries. The values must be checked though. Ordering Please provide the name and product number when ordering: Room temperature con- troller RDH10RF/SET. Valves and actuators are to be ordered as separate items. Equipment combinations Type of unit Product number...
Page 3
Room temperature display in °C Indicates a heat request Temperature setting knob Battery compartment Comfort temperature setpoint Indicates RF signal test TEST Indicates low battery power; replace batteries 3/12 Siemens Room temperature controllers CE1N3070en Building Technologies 01.03.2010...
The RDH10RF is located in a plastic housing. Two buttons are visible on the rear side when removing the baseplate. Test button Test & Learn buttons to- Learn button gether = RESET function RDH10RF 4/12 Siemens Room temperature controllers CE1N3070en Building Technologies 01.03.2010...
Simultaneously press the TEST and LEARN buttons on the rear side of the controller to Reset reset it (reset function). Simultaneously press the OVERRIDE and LEARN buttons to reset the receiver (reset function). All individual settings are reset to the default values. 5/12 Siemens Room temperature controllers CE1N3070en Building Technologies 01.03.2010...
Manual override Flash RED (No RF receive) Relay state Relay LED Relay LED From OUT to ON (First 5 seconds) Flash YELLOW YELLOW From ON to OFF (After 5 seconds) Flash YELLOW 6/12 Siemens Room temperature controllers CE1N3070en Building Technologies 01.03.2010...
Page 7
EN 301489-3 V1.4.1 Safety class III as per EN 60950-1 Pollution degree Degree of protection of housing IP20 Weight (incl. package) General RDH10RF/SET 515 g Color of housing front Signal-white RAL 9003 Housing material ABS (LCD lens: PC) 7/12 Siemens...
Page 8
All ECC countries, Norway, Iceland and Switzerland Safety class II as per EN 60 730 Degree of pollution Color Unit front Signal-white RAL 9003 Base Gray RAL 7035 Dimensions 83x104x32 mm 8/12 Siemens Room temperature controllers CE1N3070en Building Technologies 01.03.2010...
(precontrol by manual mixing valve) Thermal reset limit thermostat Cooling equipment Safety limit thermostat Room temperature controller RDH10RF Circulating pump Receiver RCR10/433 3-port valve with manual adjustment Magnetic valve 9/12 Siemens Room temperature controllers CE1N3070en Building Technologies 01.03.2010...
Page 10
Dimensions Room temperature controller Room temperature controller mounting plate Room temperature controller with fold- out stand 10/12 Siemens Room temperature controllers CE1N3070en Building Technologies 01.03.2010...
Page 11
Room temperature receiver with mount- ing plate 11/12 Siemens Room temperature controllers CE1N3070en Building Technologies 01.03.2010...
Need help?
Do you have a question about the RDH10RF/SET and is the answer not in the manual?
Questions and answers
Trmostat kombiyi algilamiyor
The Siemens RDH10RF/SET thermostat may not be detecting the boiler due to the following potential reasons:
1. Improper Pairing: The RDH10RF thermostat and the RCR10/433 receiver may not be properly paired. Ensure that the pairing process has been completed correctly using the "Learn" button on the receiver.
2. Electrical Connection Issues: Check the electrical connections of the receiver to ensure they comply with local regulations and are securely connected.
3. Power Supply Problems: Verify that the receiver is receiving the correct operating voltage (AC 230 V ±10/−15%) and that it is functioning properly.
4. Interference or Range Issues: The radio signal between the thermostat and the receiver may be obstructed or out of range. Ensure that the devices are within the recommended range and free from interference.
5. Battery Level: If the thermostat uses batteries, ensure they are properly installed and have sufficient charge, as low batteries can affect performance.
6. Reset Required: If issues persist, try resetting the receiver by pressing the "Test" and "Learn" buttons together. Re-pair the devices after the reset.
If these steps do not resolve the issue, further troubleshooting may be necessary.