Starting Problems - Toro Groundsmaster 300 Series Service Manual

Hide thumbs Also See for Groundsmaster 300 Series:
Table of Contents

Advertisement

Starting Problems (continued)
Condition
________________________________________________________________________________________________________________________________________________________
Nothing happens when start
attempt is made.
®
Groundsmaster
300 Series
Possible Cause
Battery is dead.
Loose or corroded battery cables.
Loose or corroded ground.
Fuse open.
Ammeter faulty.
Ammeter wiring loose, corroded or
damaged.
Ignition switch faulty.
Ignition switch wiring loose,
corroded or damaged.
Traction neutral switch out of
adjustment or faulty.
Traction neutral switch wiring
loose, corroded or damaged.
PTO switch out of adjustment or
faulty.
PTO switch wiring loose, corroded
or damaged.
Starter interlock relay wiring loose
corroded or damaged.
Starter interlock relay faulty.
Starter solenoid wires loose,
corroded or damaged.
Starter solenoid faulty.
Page 6 - 7
Correction
Charge battery. Replace battery if
it will not hold a charge.
Clean and tighten or repair as
necessary.
Check fuse and replace if fuse is
open. If fuse burns out often, find
and correct cause.
Test ammeter and replace if faulty.
Repair wiring.
Test ignition switch. Replace if
faulty.
Repair wiring.
Test switch and replace if faulty.
Make sure wires are connected
to "COMMON" and "NORMALLY
OPEN" (N.O.) terminals.
Repair wiring.
Test switch and adjust or replace
if faulty.
Repair wiring.
Repair wiring.
Test relay and replaced if faulty.
Clean and tighten or repair as
necessary.
Test starter solenoid. Replace if
faulty.
Troubleshooting