Getting Started - Medisana BU 550 Connect Instruction Manual

Upper arm blood pressure monitor
Table of Contents

Advertisement

Available languages

Available languages

GB
2 Useful Information / 3 Getting started
2.6 Fluctuations in blood pressure
There are many factors that can influence blood pressure. Readings can be affected
seriously by stress, fear, heavy physical exertion or the time of day at which the
measurements are taken. Your personal blood pressure values are subject to consi-
derable fluctuation during the course of the day and the year. These fluctuations
are particularly pronounced in the case of patients suffering from hypertension.
Blood pressure is usually at its highest during physical exertion and at its lowest at
night when you are asleep.
2.7 Influencing and evaluating readings
Measure your blood pressure several times, then record and compare the results.
Do not draw any conclusions from a single reading.
Your blood pressure readings should always be evaluated by a doctor who is also
familiar with your personal medical history. When using the unit regularly and
recording the values for your doctor, you should visit the doctor from time to time
to keep him updated.
When taking readings, remember that the daily values are influenced by several
factors. Smoking, consumption of alcohol, drugs and physical exertion influence the
measured values in various ways.
Measure your blood pressure before meals.
Before taking readings, allow yourself at least five minutes rest.
If the systolic and diastolic readings seem unusual (too high or too low) on several
occasions, despite correct use of the unit, please inform your doctor. This also
applies to the rare occasions when an irregular or very weak pulse prevents you
from taking readings.

3 Getting started

3.1 Inserting/changing batteries
You must insert the batteries provided before you can use your unit. The lid of the bat-
tery compartment
insert the 4 x 1,5 V batteries, type AAA / LR03 supplied. Ensure correct polarity when
inserting the batteries (as marked inside the battery compartment). Close the
battery compartment. Replace the batteries if the change battery symbol
on the display
unit has been switched on. If a flashing change battery symbol
display, the power is sufficient for approx. 10 more measurements, before the batteries
are completely empty.
WARNING - BATTERY SAFETY INFORMATION
• Do not disassemble batteries!
• Remove discharged batteries from the device immediately!
• Increased risk of leakage, avoid contact with skin, eyes and mucous
membranes! If battery acid comes in contact with any of these parts,
rinse the affected area with copious amounts of fresh water and seek
medical attention immediately!
• If a battery has been swallowed seek medical attention immediately!
• Replace all of the batteries simultaneously!
22
is located on the underside of the unit. Open it, remove it and
(together with "Lo") or if nothing appears on the display after the
appears
appears on the
i
i
i
i
i

Hide quick links:

Advertisement

Table of Contents
loading