Procedure To Install Windows In San/Iscsi Storage Device; Presetting - Fujitsu PRIMEQUEST 2000 Series Installation Manual

Primequest 2000 series
Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

CHAPTER 4 Installation of Operating System and bundled software

4.3 Procedure to install Windows in SAN/iSCSI storage device

-
When the OS starts "Fast TSC calibration failed" appears in RHEL message.
This message is output when access performance to the PIT (Programmable Interval Timer) is less than the
expected value in TSC (Time Stamp Counter) adjustment process of OS boot.
This cause is virtualization overhead of PIT, which is performed by the Extended Partitioning Firmware.
But in this case, the system does not be affected because the OS switches automatically to the HPET (High Precision
Event Timer).
4.3
Procedure to install Windows in SAN/iSCSI storage device
Here, the procedure to install Windows in SAN storage device is explained. Start the installation after confirming the MMB
configuration setting and successful login to the MMB. For the settings of SAN storage device, FC-card,
Network Adapter and NIC for iSCSI
(C122-E206EN) .

4.3.1 Presetting

The following settings are done if necessary.
1.
LUN of SAN storage device is set.
2.
[PCI ROM Priority] of BIOS is set.
- For the UEFI Install
- Set [Device Manager]-[PCI Subsystem Configuration]-[PCI ROM Priority] of BIOS menu to "EFI Compatible
ROM".
- For the UEFI Install:
- Set [Device Manager]-[PCI Subsystem Configuration]-[PCI ROM Priority] of BIOS menu to "Legacy ROM".
- Set [Device Manager]-[PCI Subsystem Configuration]-[OpROM Scan Configuration] of BIOS menu to "Enable"
only for booting Device.
3.
BIOS is set to recognize LUN of FC card.
For the settings of FC card,
SAN Boot Environment Configuration Manual (C122-E206EN) .
4.
The partition settings in MMB are confirmed after the internal HDD/SDD of PRIMEQUEST is removed.
- SB/IOU configuration is set
See
"3.4.1 Setting the partition
- Console redirection is set
See
"3.4.6 Settings of Console
- Video redirection: Enable
- Virtual media: Enable
- Various modes are set
See
"3.4.5 Various mode
5.
Only LUN which becomes the installation target of SAN storage device is connected to the partition of
PRIMEQUEST.
For the settings of SAN storage device, see "Attached manual in the SAN storage device".
6.
I/O space is allocated in FC card of the boot path target and SAS RAID controller, RAID card. For the allocation of I/O
space, see
Administration Tool Reference (CA92344-0539).
Boot, see PRIMEQUEST 2000 Series SAN Boot Environment Configuration Manual
Converged Network Adapter and NIC for iSCSI
configuration"
Redirection"
settings"
"5.5.1 How to use sadump
(Linux)" and
"3.4.5 Various mode
62
Converged
Boot, see PRIMEQUEST 2000 Series
settings" of PRIMEQUEST 2000 series
CA92344-0536-01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primequest 2800e

Table of Contents