Premier Elite 24,24-W, 48,48-W, 88, 168 & 640 Installation Manual
2-Wire Smoke Detector
Panel Output 1 can be used for connecting up to 10, 12V 2-Wire smoke detectors.
C ontrol
Panel
+ V Out
E nable
S moke
To enable 2-Wire smoke detection on panel output 1, a jumper link must be fitted across the bottom two pins of JP10. The Area Option '2-Wire
Smoke' also needs to be enabled (see page 60).
2-Wire smoke detectors can only be connected to panel output 1
Expander Auxiliary Input
This input can be used for monitoring a remote power supply that has a voltage free output for the following three conditions: AC Mains Fail, Battery Fail,
12V Fail and Tamper.
When the Auxiliary Input is programmed as 'PSU Monitor' the system will respond as follows: