2-Wire Smoke Detector; Expander Auxiliary Input - Texecom Premier Elite 24 Installation Manual

Table of Contents

Advertisement

Premier Elite 24,24-W, 48,48-W, 88, 168 & 640 Installation Manual

2-Wire Smoke Detector

Panel Output 1 can be used for connecting up to 10, 12V 2-Wire smoke detectors.
C ontrol
Panel
+ V Out
E nable
S moke
To enable 2-Wire smoke detection on panel output 1, a jumper link must be fitted across the bottom two pins of JP10. The Area Option '2-Wire
Smoke' also needs to be enabled (see page 60).
2-Wire smoke detectors can only be connected to panel output 1

Expander Auxiliary Input

This input can be used for monitoring a remote power supply that has a voltage free output for the following three conditions: AC Mains Fail, Battery Fail,
12V Fail and Tamper.
When the Auxiliary Input is programmed as 'PSU Monitor' the system will respond as follows:
Tamper
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Open
INS176-9
+ V In
-RLED
+ V In
OV
Aux
Input
12V Fail
Battery Fail
Closed
Closed
Closed
Closed
Closed
Open
Closed
Open
Open
Closed
Open
Closed
Open
Open
Open
Open
-
-
+ V Out
OV
A/C Fail
Resistance
Closed
0R
Open
2K2
Closed
4K7
Open
6K9
Closed
10K
Open
12K2
Closed
14K7
Open
16K9
-
O/C
Remote LED
(Optional)
+ V In
-RLED
+ V Out
1k EOL
OV
Response
No Faults
AC Fail
Battery Fail
Battery Fail + AC Fail
12V Fail
AC Fail + 12V Fail
Battery Fail + 12V Fail
AC Fail + Battery Fail + 12V fail
Lid Tamper
Installation
-RLED
35