Log Event
### ARM FAILED
### Flt Alarm
### Mask Alarm
### Test Failed
### Tested OK
#,# RESET AREAS -
AC Off Alarm
ALARM ABORT
ALARM Active
Anti-Code Reset
AREA Armed
AREA Disarmed
ARMED WITH L/F
ARMING FAILED
ARMING SUITE #
ATS FAILED
ATS FLT Alarm
AUTO TEST CALL
AUX #,# Tamper
AV CLEARED by ##
BELL #,# Tamper
BELL Active
BELL FUSE Alarm
BOX LID Tamper
CHARGER FAULT
CIE Reset
CODE #,# Tamper
Com??? Line Fault
COM PORT Alarm
CONFIRMED ALARM
CONFIRMED PA
CONFIRMED INTRUDER
CORRUPT EVENT
CROSS ### Alarm
DATA CHANGED
DATE CHANGED
DEFAULTS LOADED
DEFERRED
DOOR #,#
DOWNLOAD START
DOWNLOAD END
DURESS
Engineer Reset
ENTRY Area ##
EXIT Area ##
EXP #,# Reset
EXP #,# Line Fault
EXP #,# LOST
EXP #,# Tamper
EXP ## Low Voltage
F_PA ##
Fault Override
FIRE ### Active
FIRE ### Tamper
FIRST KNOCK ###
FUSE #,# Alarm
GSM MODULE LOST
iD Loop# Tamper
Key switch Reset
KSW ### Disarmed
LOG ALERT
LOG CLEARED
LOW BAT Alarm
LOW V #,# Alarm
MANUAL TEST CALL
MIC ## TESTED
Monitored Alarm
No RF Signal ###
PA From Remote FOB
Panel Line Fault
PART Armed
PART 1 Armed
PART 2 Armed
PART 3 Armed
POWERED UP
POWER O/P FAULT
POWER UNIT FAILURE
PROG. END
PROG. START
PSUac ## Alarm
PSUbat## Alarm
PSUvol## Alarm
INS176-9
An exit fault from Zone ### has caused the system to fail to arm
Zone ### has detected a Fault condition
Zone ### has detected a Mask condition
Zone ### has activated whilst it has been on soak test
Zone ### has activated during the walk test
Area have been reset using keypad #,# following an Intruder alarm
The control panel has detected an AC Mains failure
An Open After Alarm-Abort has occurred for area ?
An Intruder alarm signal has been activated for area ?
A reset has been performed using the Anti-code reset procedure
Area ? has been armed
Area ? has been disarmed
The system has been armed with a Line Fault condition present
A Exit Error-Arm Fail has occurred on area ?
Area Arm Suite # was used to arm the system
The Communicator has failed to report to the Alarm Receiving Centre
There is a problem with the telephone line
An Automatic test call has been initiated
An Auxiliary Tamper input from device #,# has been activated
The Audio Verification unit has been cleared down by user ##
A Bell Tamper input from device #,# has been activated
The Bell output has been activated for area ?
The control panel Bell Fuse has failed
The control panel lid has been removed causing a Tamper alarm
Battery Charge Current has Failed
The internal processor has failed its self checks.
Too many invalid key presses have caused a tamper alarm from keypad #,#
The Com300, 2400 or ISDN has detected a line fault
A com port has generated an alarm
Two or more detectors have activated, resulting in a confirmed alarm condition
Two or more PA zones have activated, resulting in a confirmed PA alarm condition
Two or more detectors have activated, resulting in a confirmed Intruder condition
No event has been stored in memory
A Verified Cross Zone (Beam Pair) Alarm has occurred from zone ###
Programming data has been changed
The control panel Time has been changed
The factory default values have been loaded into memory
The arming mode was deferred for area ?
Door #,# has been opened by a user with Door Control
An Upload/Download has been initiated
The Upload/Download has finished
User ## has entered a Duress Code at a keypad
A reset has been performed using an Engineers code
The Entry mode has been started for area ?
The Exit mode has been started for area ?
A reset has been performed using the input on expander #,# (programmed as reset)
The Input on expander #,# (programmed as line fault) has been activated
Expander ## has been lost from the network
The cover of expander #,# has been removed
Expander #,# has detected that its supply voltage is low
A Panic Alarm from a Radio FOB has been generated
The system has been armed with a Fault condition present by a user
Zone ### (programmed as Fire Alarm) has caused an alarm
Zone ### (programmed as Fire Alarm) has caused an Tamper alarm
Zone ### (which is programmed as double knock) has activated for the first time
The Auxiliary 12V Fuse in device #,# has failed
The GSM Module has lost communications with the control panel
There is a short circuit on iD loop # on the iD expander
A reset has been performed using a key switch
A Keyswitch zone type has been activated (zone number ###)
80% of the Event Log has filled (since the last Upload/Download)
The event log has been erased
The control panel has registered a low battery condition
Expander #,# has detected that's its supply voltage is low
A Manual test call has been initiated
Microphone ## on the Audio Verification Module has been tested
A zone programmed as key tube has caused an alarm
The Wireless receiver has detected a signal loss from zone ###
A PA has been generated from a Remote Fob
The control panel line fault input has been activated
Area ? has been Part Armed
Part Arm 1 has been selected
Part Arm 2 has been selected
Part Arm 3 has been selected
System Power Up (without doing a factory restart)
The system has generated a Power Output Fault see Table Power ID Fault on Page 98
The system has generated a rate of voltage failure
The Engineer has logged out of the Programming menu
An Engineer code has been entered
An expander input programmed as PSU Monitor control panel has detected an AC Mains failure
An expander input programmed as PSU Monitor control panel has detected a Battery fault
An expander input programmed as PSU Monitor control panel has detected a 12V Output failure