1-10. Installing the Optional Board to INPUT A and INPUT B
For both INPUT A and INPUT B slots, the optional board, LKRI-003 or LKRI-005 can be installed.
The installing procedure for each slot is same.
n
For INPUT A slot, LKRI-005 is installed before shipment. Replace it as necessary.
Parts information
. Fixed Plate (HIF) 320: 4-159-161-01 (For LKRI-003)
. Fixed Plate (DIF) 320: 4-159-162-01 (For LKRI-005)
. Handle:
Procedure (LKRI-003)
1. Remove the six screws, then remove the panel (HIF-44)
and fi nger holder (HIF).
2. Attach the fi xed plate (HIF) 320 using the six screws
removed in step 1.
3. Attach the two handles to the fi xed plate (HIF) 320.
SRX-R320
3-172-089-01 (Using 2 pcs)
LKRI-003
B3 x 8
Panel (HIF-44)
Fig. 1-10a
LKRI-003
Handle
B3 x 8
Handle
Fig. 1-10b
Finger holder (HIF)
Fixed plate (HIF) 320
1-27