Panel display
Code
(last 4
Large LCD
digits)
1410
No ink tank
to
loaded.
141C
Check ink tank.
200A
Paper size not
detected. Press
Load/Eject
and reload the
paper.
Paper size not
detected. Reload
paper.
Paper size not
detected. Press OK
and
reload the paper.
200B
Paper size not
detected. Reload
paper.
200C
Paper size not
detected.
Press Load/Eject
and reload the
paper.
Paper size not
detected.
Reload paper.
Paper size not
detected.
Lift the release
lever and reload
the paper.
Small
Small
LCD 1
LCD 2
Ink tank not installed (continued use allowed)
The ink tank is not installed but a sufficient
volume of ink is left in the subtank.
Displayed only on models having a subtank.
This occurs in cases such as when the ink
tank cover is opened during printing, and the
ink tank is removed. (XX: Displays
applicable colors)
Last 2 digits: 10:Bk, 11:Y, 12:M, 13:C, 14:PM,
15:PC, 16:MBk1, 17:MBk2, 18:GY, 19:PGY,
1A:R, 1B:V, 1C:GR
Paper
Size
Paper size detection failure
Please
Undetect
Cannot detect the paper width (poorly
Reload
ed
positioned paper).
Press
↑ Key
Paper
Size
Paper size detection failure
Please
Undetect
Paper is invalidly positioned on the platen.
Reload
ed
Press
↑ Key
Paper
Size
Paper size detection failure
Please
Undetect
Cannot detect the leading edge of the paper.
Reload
ed
The leading edge of paper has been located
Press
by coarse detection but not by a second
↑ Key
round of fine detection (up to 300 mm)
(semi-transparent paper).
(This is the message when the release lever
operation is not necessary.)
Papr Size
Press
Paper size detection failure
Undetecte
Online
Cannot detect the leading edge of the paper.
d
Key
The leading edge of paper has been located
and
by coarse detection but not by a second
Reload
round of fine detection (up to 300 mm)
(semi-transparent paper).
Explanation/Detection sequence
2-9
Chapter 2 Indexes by Case
Remedial Action
(★: Reference fault
isolation procedure
or tool)
①Mount the tank.
②Failure of
remaining ink
detection
system.
(Replace the
supply unit
/check the
bundled wires.)
Go to ★2010
(P3-12)
Go to ★2010
(P3-12)
Go to ★2010
(P3-12).