Test points layout of Main Unit.
ADJUSTMENT OF EP STILL PIC-
TURE VERTICAL SYNC
Measuring
Monitor TV
instrument
Mode
EP still picture playback
Input signal
Self-recording tape
Test point
Monitor screen
CH '/" (TR
Control
Specification
No Vertical jitter
Figure 2-2.
1. Playback the EP Self-recorded tape in the still mode.
2. Using the CH '/" (TR
3. Then press the STOP button to stop the tape.
Note:
±
/
) buttons
The data of this adjustment is memorized to the E
ROM IC.
41
±
/
control or inside the front cover, make adjustment so
that the vertical jitter becomes minimum.
13VT-K100/150
13VT-CK10
) buttons on the remote
2
P-

Advertisement