3-38 Windows Setup and Operation
Restart the PCI module.
4.
From the ft server utility, click [Up] of [Bring Up/Bring Down] to the PCI module
which was stopped in the step 3, and the PCI module will be started. Once the PCI
module is started, PCI module diagnosis, mirror volume duplication and PCI module
duplication are performed.
IMPORTANT:
If ARCserve Backup or Backup Exec is installed and the backup software related
services are operating at the time of PCI module startup, the phenomenon in which
the PCI module is not duplexed properly may occur. Thus be sure to stop the services
before starting the PCI module.
1. Start [Services] from [Administrative Tools] of [Control Panel].
2. Select a service of backup software.
3. Choose "Stop" from the "Action" menu.
4. Repeat 2 and 3 for all services of the backup software.
The PCI modules' status LEDs changes as shown below:
[Indications of the status LEDs]
Immediately after the PCI module startup until the completion of diagnosis:
1
PRIMARY LED
2
DISK ACCESS LED
3
System FT LED
When duplication of disks is started after the completion of PCI module diagnosis:
*
The status of LEDs varies depending on the method of disk duplication.
1
PRIMARY LED
2
DISK ACCESS LED
3
System FT LED
LED
LED
LED
LED
Secondary
-
-
System
-
Secondary
-
Amber or Green
blinking (Green
when accessing to
HDD)
System
-
Primary
Green
Amber or Green
blinking (Green
when accessing to
HDD)
Primary
Green
Amber or Green
blinking (Green
when accessing to
HDD)