Specifications

Environmental specifications

Specification
Temperature
Operating
1
Non-operating
Maximum rate of temperature
change
Operating
2,3
Non-operating
Relative humidity
(noncondensing)
Operating
Non-operating
Maximum wet bulb
temperature (non-condensing)
Operating
Non-operating
Altitude
Operating
2
Non-operating
Maximum rate of altitude
change
Operating
Non-operating
1
All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
2
The type and number of options installed can limit the upper limit.
3
System performance may be reduced if operating with a fan fault above 30ºC (86ºF).

Mechanical specifications

Specification
Dimensions
Height
Depth
Width
Value
10°C to 35°C (50°F to 90°F)
30°C to 60°C (-22°F to 140°F)
10°C/hr (18°F/hr)
20°C/hr (36°F/hr)
10% to 90%
5% to 95%
28°C (82.4°F)
38.7°C (101.7°F)
3,050 m (10,000 ft)
9144 m (30,000 ft)
457 m/min (1,500 ft/min)
457 m/min (1,500 ft/min)
Value
4.32 cm (1.69 in)
70.00 cm (27.56 in)
44.81 cm (17.64 in)
Specifications 88