Operation examples (continued)

Operation example 3

Setting the timer recording operation (1). Switching the
number of the cameras operated and recording rate
depending on the time period and day of the week.
Operation
• Uses <Set Recording Pattern A (Normal/Timer)> from
08:00 to 18:00 on Monday to Friday.
• Uses <Set Recording Pattern B (Timer)> from 18:00
to 08:00 (alarm recording operation : motion detection
B) on Monday to Friday.
• Uses <Set Recording Pattern B (Timer)> from 08:00
to 08:00 (on the following day) on Saturday and
Sunday.
08:00
From Monday
<Recording Pattern A>
to Friday
08:00
Saturday and
Sunday
Settings
<Recording settings (Set Recording Pattern A (Normal/
Timer))> (
see pages 51 to 53)
Setup Menu
1
Recording
1
Set Recording Pattern A (Normal/Timer)
Camera Check
1
Normal Recording Menu
2
D
D
1. Execute camera check to automatically detect the
step
cameras with video signal input.
2. Use "Easy" to set the desired recording rate for
step
normal recording.
3. Use "Manual" to set the recording rate of
step
unnecessary cameras to "– – –."
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
92
18:00
08:00 (next day)
<Recording
Pattern B>
08:00 (next day)
<Recording Pattern B>
Recording Setting A-Normal (Easy)
Recording Setting A-Normal (Manual)
<Recording settings (Set Recording Pattern B (Timer))>
(
see pages 51 to 53)
Setup Menu
1
Recording
2
Set Recording Pattern B (Timer)
Camera Check
1
Normal Recording Menu
2
D
3
Alarm Recording Menu
D
Alarm Trigger In/Out
5
4. Execute camera check to automatically detect the
step
cameras with video signal input.
5. Use "Easy" to set the desired recording rate for alarm
step
recording.
6. Use "Easy" to set the recording rate of all the camera
step
numbers for normal recording to "– – –."
1
step
7. Set the alarm recording trigger to "MD-B."
step
<Motion detection settings> (
2
step
Setup Menu
3
Motion Det
3
step
Set Motion Detection Pattern B
2
A+12
13
Test Mode
8. Set the motion detection settings for Motion B.
step
Recording Setting B-Normal (Easy)
Recording Setting B-Alarm (Easy)
see pages 58 and 59)
Motion Mask Settings
4
step
6
step
5
step
7
step
8
step