Dedicated Motor Outline Dimension Drawings - Mitsubishi Electric FR-A700 Manual

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Dedicated motor outline dimension drawings

SF-V5RU(H)
1K
Connector (for encoder)
MS3102A20-29P
L
A
KA
Exhaust
Suction
Direction of
cooling fan wind
F
F
Mark for earthing
N
(grounding)
W
Sliding distance
S
Frame leg viewed from above
Section AA
SF-V5RU(H)
,
11K
15K
Connector (for encoder)
MS3102A20-29P
A
KA
Exhaust
Suction
With guard
wires
Direction of
cooling fan wind
Mark for earthing
F
(grounding)
Earth (ground)
terminal (M8)
Sliding distance
W
S
Frame leg viewed
Section AA
Dimensions table
SF-V5RU
SF-V5RU1
SF-V5RU3
SF-V5RU4
Output
Output
Output
Output
(kW)
(kW)
(kW)
(kW)
1.5
2.2
1.5
3.7
2.2
1.5
5.5
3.7
2.2
7.5
5.5
3.7
1.5
11
7.5
5.5
2.2
15
11
7.5
3.7
18.5
22
15
11
18.5
15
5.5
30
30, 45
22, 30
18.5
7.5
55
37
22, 30
11, 15
Note) 1. Install the motor on the floor and use it with the shaft horizontal.
2. Leave an enough clearance between the fan suction port and wall to ensure
adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the
load side.
97
KL
50
B
40
D
A
A
XB
E
E
M
Earth (ground) terminal (M5)
15
For cooling fan (A, B)
A
B
U
,
,
18K
22K
L
KL
110
B
D
90
A
A
50
XB
E
E
F
M
N
4
from above
For cooling fan (A, B, C)
Frame
Mass
No.
(kg)
A
B
C
D
E
F
90L
24
256.5
114
90
183.6
70
62.5
100L
33
284
128
100
207
80
70
112M
41
278
135
112
228
95
70
132S
52
303
152
132
266
108
70
132M
62
322
171
132
266
108
89
160M
99
412
198
160
318
127
105
160L
113
434
220
160
318
127
127
138
180M
438.5 225.5
180
363
139.5 120.5
160
180L
200
457.5 242.5
180
363
139.5 139.5
238
200L
483.5 267.5
200
406
159
152.5
255
225S
320
500
277
225
446
178
143
(1500r/min series)
SF-V5RU(H)
2K
Connector (for encoder)
MS3102A20-29P
A
KA
Exhaust
Suction
Direction of
cooling fan wind
F
Mark for earthing
(grounding)
Earth (ground) terminal (M5)
For motor (U, V, W)
Thermal protector (G1, G2)
V
W
G1
G2
Earthing (grounding) terminal
SF-V5RU(H)
30K
Connector (for encoder)
MS3102A20-29P
Suction
With guard
wires
Direction of
Mark for earthing
cooling fan wind
(grounding)
For motor (U, V, W)
Earth (ground)
terminal (M12)
Earthing (grounding)
terminal
For thermal protector (G1, G2)
Motor
H
I
KA
KG
KL(KP)
L
M
ML
198
53
65
220(210)
425
175
203.5
230
65
78
231
477
200
212
226
253
69
93
242
478
230
242
265
288
75
117
256
542
256
268
265
288
94
117
256
580
256
268
316
367
105
115
330
735
310
316
367
127
115
330
779
310
359
410
127
139
352
790
335
359
410
146
139
352
828
335
401
145
487
(546)
909
390
446
145
533
(592)
932
428
3 The size difference of top and bottom of the shaft center height is
4 The 400V class motor has -H at the end of its type name.
(standard horizontal type)
,
,
,
3K
5K
7K
L
B
Q
KL
QK
D
A
A
40
XB
F
E
N
M
W
ML
S
Section AA
,
,
,
37K
45K
55K
L
140
A
B
110
KA
Exhaust
A
A
70
XB
F
F
E
N
W
S
Section AA
Make sure to earth the earth terminal of the frame installation foot
as well as the earth terminal in the terminal box.
N
XB
Q
QK
R
S
T
150
56
168.5 24j6
7
180
63
60
45
193
28j6
7
180
70
60
45
200
28j6
7
180
89
80
63
239
38k6
8
218
89
80
63
258
38k6
8
254
108
323
42k6
8
298
108
345
42k6
8
285
121
351.5
48k6
9
5.5
323
121
370.5 55m6
10
361
133
425.5 60m6
342
149
432
65m6
E
Sliding distance
4
Frame leg viewed
from above
D
E
M
Sliding distance
4
Frame leg viewed
from above
(Unit: mm)
Terminal Screw
Size
U
W
U,V,W A,B,(C) G1,G2
4
8
M6
M4
M4
4
8
M6
M4
M4
4
8
M6
M4
M4
5
10
M6
M4
M4
5
10
M6
M4
M4
5
12
M8
M4
M4
5
12
M8
M4
M4
14
M8
M4
M4
6
16
M8
M4
M4
M10
M4
M4
M10
M4
M4
0
0.5