Application To Constant-Torque Motors; Application To Vector Control Dedicated Motors (Sf-V5Ru) (55Kw Or Less); Sf-Hrca Type; Standard Specifications (Indoor Type) - Mitsubishi Electric FR-A700 Manual

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

SF-HRCA type

Continuous operation with 100% torque even at low
speed of 3Hz is possible. (when using real sensorless
vector control)
For the 37kW or less, load torque is not need to be
reduced even at a low speed and constant torque (100%
torque) continuous operation is possible within the range
of speed ratio 1/20 (3 to 60Hz). (The characteristic of
motor running at 60Hz or more is that output torque is
constant.)
Installation size is the same as that of the standard motor
Note that operation characteristic in the chart below can
not be obtained if V/F control is employed.
Continuous rated range of use (real sensorless vector control)
60Hz Torque Reference (when inverter is 0.4kW to 37kW)
Maximum torque for short time (0.4kW to 3.7kW)
200
Maximum torque
for short time
(5.5kW to 37kW)
150
Continuous
operation
torque
100
70
(60)
(%)
63
(50)
50
(45)
45
(40)
0
0.3
3
20
Output frequency (Hz)
Values in parenthesis apply to the 0.4kW to 0.75kW
Please contact us separately for the motor constants during real sensorless vector control.

Application to vector control dedicated motors (SF-V5RU) (55kW or less)

Motor torque
When the vector control dedicated motor (SF-V5RU) and inverter are used, the torque characteristics are as shown below.
When inverter is 1.5kW to 22kW
Maximum torque for short time
150
Continuous
operation torque
100
75
(%)
50
0

Application to constant-torque motors

220V
200V
60
120
Constant power
1500
3000
Speed (r/min)

Standard specifications (indoor type)

Output
Number
Frequency
(kW)
of Poles
Range
0.4
0.75
1.5
2.2
3 to 120Hz
3.7
5.5
7.5
11
4
15
18.5
3 to 100Hz
22
30
37
45
3 to 65Hz
55
60Hz Torque Reference (when inverter is 45kW to 55kW)
150
Continuous
operation
torque
100
80
70
63
50
(%)
45
0
0.3
3
10
20
Output frequency (Hz)
When inverter is 30kW to 55kW
Maximum torque for short time
150
Continuous
operation torque
Constant power
100
94
(%)
63
60
40
0
1500
2400
Speed (r/min)
Common Specifications
Standard frequency 60Hz
Rotation direction (CCW) is
counterclockwise when viewed
from the motor end
Lead wire
3.7kW or less.....3 pcs.
5.5kW or more...6 or 12 pcs.
Ambient temperature: 40 °C
maximum
Protective structure is JP44
Maximum torque
for short time
220V
200V
60
120
Reduced output
3000
94

Hide quick links:

Advertisement

Table of Contents
loading