ABB-Welcome
Auxiliary power
supply
Article number: 83310-500
Functions
»
Additional supply device of the Busch-Welcome system to
increase the number of connectable indoor stations
Technical data
Operating temperature: -5°C–+45°C
Protection: IP 20
Single-wire clamps: 2 x 0.6 mm
Fine-wire clamps: 2 x 0.6 mm
Bus voltage: 28 V–±2 V; 1 A
Mains voltage: 100 – 240V; 50/60 Hz; 0.9 A
connection cross section for 230 V: 1.5 mm² – 2.5 mm²
Indoor stations for direct connection: 4
Size: 8 TE
QR-Code service
www.busch-jaeger-catalogue.com/
8300-0-0126,artikel.html
–2 x 1 mm
2
2
–2 x 0.75 mm
2
2
ABB-Welcome
Video indoor distributor
Article number: 83320/2 U-500
Article number: 83320/2-500
Functions
»
Distributes the video signal of the ABB-Welcome video
outdoor station in the building
»
The video signal of the entrance door can be received in
different apartments or in several rooms with the aid of the
distributor
»
Is available as MDRC unit or for flush-mounted installation
»
Is only required when installing stub lines and rising mains
Technical data
Operating temperature: -5°C–+40°C
Protection: IP 20
Single-wire clamps: 2 x 0.6 mm
Fine-wire clamps: 2 x 0.6 mm
Bus voltage: 28 V – ±2 V
Size 83320/2 U: for installation in a deep flush-mounted
socket
Größe 83320/2: 2 MW
QR-Code service
For flush-mounting
www.busch-jaeger-catalogue.com/
8300-0-0121,artikel.html
MDRC unit
www.busch-jaeger-catalogue.com/
8300-0-0120,artikel.html
User Manual ABB-Welcome | Overview of Range 49
–2 x 1 mm
2
2
–2 x 0.75 mm
2
2