Stop switch

Dismantling
Remove the earth screw (A) and cable (B).
Press the switch's securing tabs (C) towards
each other and push out the switch.
Cleaning and Inspection
Clean the switch and check its resistance as
follows:
Connect an ohm meter as shown in the fig.
The resistance should be:
In the stop position
In the run position
Assembly
Press the switch into the socket on the tank unit.
Fit the earth screw (A) and cable (B).
Note! On some models the earth cable should
be connected to the earth screw.
SAFETY EQUIPMENT
less than 0.1 ohm.