Cleaning and Inspection
!
WARNING!
The coating on and in the catalytic
converter element (A) is hazardous
to your health if touched. Wear
protective gloves when working on
a catalytic converter
Assembly
Clean all contact surfaces.
Other saws
If the saw is equipped with a spark arrester
(C), fit this.
Fit the cooling plate (B) if
fitted, gasket and muffler on
the cylinder.
Other saws
Tighten all bolts using the tightening
torque set out in the "Service data".
B
C
A
50
– English
SAFETY EQUIPMENT
Saws 36 and 41
242 Cat
1
See "Service data" regarding tightening torques.
1. Secure the muffler on the cylinder using the two
bolts (D).
2. Assemble the muffler components using the four
bolts (E).
3. Secure the muffler to the crankcase using the two
bolts (F) and Loctite.
Clean all parts and check the following:
• That the muffler and muffler mountings are
not cracked or otherwise damaged.
• That the gaskets are OK.
Assemble the muffler and fit to the
cylinder. Tightening torque, see page
20.
!
WARNING!
The coating on and in the cata-
lytic converter element (A) is
hazardous to your health if
touched. Wear protective gloves
when working on a catalytic
converter
Only specially treated bolts may be used on
the catalytic converter (high temperature).
See spare parts catalogue.
D
E
F