2-5

Controller (slave station) system setting

The station address must be set so that the controller can be correctly identified as a slave
station on the PROFIBUS system. Communication speed is automatically recognized.
The PROFIBUS unit station address is set from the HPB. This setting is enabled after the
controller is restarted.
2-5-1

Validating the PROFIBUS unit

Before the PROFIBUS unit can be used, it must first be set as follows, to allow it to be
identified by the controller.
1)
Press
2)
Press
tion display and then press
3)
Press
4)
The current PROFIBUS unit identity sta-
tus appears on the display.
Now, using the number key pad, enter a 1
to make the PROFIBUS unit identifiable
from the controller or enter a 0 to prevent
it being identified from the controller, and
then press the
5)
When entry is finished, the screen returns
to 4).
(SYS) on the initial screen.
F3
(next) to switch to the func-
F4
F2
(DEV).
F1
key.
11
CHAPTER2 PROFIBUS Unit
[MENU]
select menu
1EDIT2OPRT3SYS 4MON
[SYS]
(OPT).
select menu
1SAFE2OPT 3UTL 4next
[SYS-OPT]
select menu
1DEV 2NODE3SPD 4next
[SYS-OPT-DEV]
PROFIBUS= 0
0:invalid 1:valid
[SYS-OPT-DEV]
PROFIBUS= 1
0:invalid 1:valid