FUEL SENSOR (setting fuel sensor)/CALIBRATION (setting correction value)

FUEL SENSOR (setting fuel sensor)

You can set the fuel sensor type that is con-
nected to this meter.
1.
Turn the engine off and the engine start
switch to ON.
2.
(4 seconds): To activate the cus-
tom mode.
3.
(2
times):
between the setting function names.
4.
: To switch to the change settings
display.
5.
: Press to switch between the fuel
sensor types.
ABYC (US)
EUROPE
YAMAHA
Blinks
6.
(1 second): To change the fuel
sensor type and return to the custom
mode selection display.
7.
(1 second): To return to the nor-
mal display.
Press
to
switch

CALIBRATION (setting correction value)

You can calibrate the displayed fuel flow
value within –7 to +7 percent. The difference
in the fuel consumption display and the
actual fuel consumption is calibrated.
Checking the calibration value:
1.
Operate the outboard motor on a full
tank of fuel.
2.
After operating the outboard motor, fill
the fuel tank. Compare the amount of
fuel filled into the fuel tank with the fuel
consumed shown on the fuel consump-
tion display and set the calibration value
to the difference if necessary.
Changing the calibration value:
1.
Turn the engine off and the engine
switch to ON.
2.
(4 seconds): To activate the cus-
tom mode.
3.
(3
times):
between the setting function names.
4.
: To switch to the change settings
display.
5.
: Press to switch between the cali-
bration values.
Blinks
6.
(1 second): To change the cali-
bration value and return to the custom
mode selection display.
61