Setting an SNMP trap destination
11.
When you install NEC ESMPRO Manager and NEC ESMPRO Agent on the same
computer, specify the IP address assigned to the network card or the host name as the
SNMP trap destination for the computer, instead of the loop back address 127.0.0.1.
If you specify 127.0.0.1, "unknown server" may be displayed on the AlertViewer.
On the other hand, you may need to specify 127.0.0.1 for a computer not connected to the
network. For more information, see "Settings on standalone environments without
network connections" below.
If the following is displayed on the AlertViewer even when you have specified as above,
Component: {unknown server}
Address:
change the IP address to 127.0.0.1 on the properties of the server icon on the Operation
Window.
Settings on standalone environments without network connections
12.
When you install the NEC ESMPRO Manager and the NEC ESMPRO Agent on a
machine together, if the machine is not connected to the network take the following steps
to monitor the machine itself:
– Specify 127.0.0.1 for Start Address and End Address as a range for the Auto-
discovering..
– Specify 127.0.0.1 for the SNMP trap destination.
If you have already registered server icons, execute AutoDiscover after deleting the icons.
About the NEC ESMPRO User Group
13.
Since security for the NEC ESMPRO Manager is managed by the NEC ESMPRO User
Group, the NEC ESMPRO never starts without accessing this group.
Note the following:
1) Do not delete/change the NEC ESMPRO User Group after installing the NEC
ESMPRO Manager.
2) When the NEC ESMPRO User Group is registered as a global group member, it is
necessary to start the Domain Controller before the Manager machine boots.
About the threshold dialog for temperature sensor
14.
For some servers, only the Fatal status may be displayed on the dialog for setting
threshold vales of temperature sensor. In this case, the sliders show yellow as normal
status, but green is displayed as the actual status color when temperature of a target
machine is lower than the specified Fatal limit.