Assigning User Code Authority Levels - GE NX-108E - Security NetworX NX-4 System User Manual

Networx series led keypad
Hide thumbs Also See for NX-108E - Security NetworX NX-4 System:
Table of Contents

Advertisement

ASSIGNING USER CODE AUTHORITY LEVELS

Assign authority levels to users by following the steps below. Assign user codes before assigning authority levels.
Your system must be in the disarmed state to change user code authority levels.
Step 1
Press [r]-[6].
Step 2
Enter a "Master Arm/Disarm Code".
NOTE: Someone changing the authority of another person can only add or remove partition
authorization for partitions to which they have access.
Step 3
The ready light will flash.
Step 4
Enter the 2-digit (applies to NX4/6/8) or 3-digit (applies to NX8E) user number. Always use leading
zeros when necessary, i.e. "004" for user number 4.
Step 5
Lights illuminated indicate the authority levels assigned to this code. An explanation of the lights is
listed below. You may toggle (turn on/off) the authority level by pressing the number for that
authority level.
LIGHT
Step 6
Press the [r] key. The ready light will flash. This moves you to the partition enable. (The user has
access in partitions that are illuminated.)
Step 7
The illuminated numbers indicate each partition where the user has access. To change any of the
partitions where the user has access, press numbers corresponding to areas where you want to
give the user access or deny access. (Example: If zone light #2 is lit, then the user is assigned
access to partition #2. By pressing the [2] key, the light will go off, denying access to partition #2.
Refer to chart shown below.
LIGHT
Step 8
When the partitions are assigned, press the [r] key. This returns you to Step 3 previously
mentioned. At this point you may enter another user number to assign authority level. Repeat
Steps 4 - 8 until you have assigned authority levels to all user numbers.
Step 9
Press the [#] key to exit the Assigning Authority Level Program.
NX-108/116/124E User manual
AUTHORITY LEVELS IF LIGHT 8 IS OFF
1
Reserved
(Note: Do not change if on.)
2
Arm Only
3
Arm Only After Close Window
4
Master Arm/Disarm (can program other codes)
5
Arm/Disarm
6
Bypass Zones
7
Open / Close Reporting
8
If this light is on, this code is programmed as a function
code. Do not change, Press [#] - [#] to exit.
PARTITIONS ASSIGNED
1
Partition 1
2
Partition 2
3
Partition 3
4
Partition 4
5
Partition 5
6
Partition 6
7
Partition 7
8
Partition 8
Page 13
10/11/05

Hide quick links:

Advertisement

Table of Contents
loading