Chapter 5
Code
Description
0803h
DiagTools Error
0804h
DiagTools Error
0805h
DiagTools Error
0806h
DiagTools Error
0810h
Speaker test failed
0811h
DiagTools Error
0812h
DiagTools Error
0813h
DiagTools Error
0814h
DiagTools Error
0815h
DiagTools Error
0816h
DiagTools Error
0830h
DiagTools Error

Video Test

The Video Test Menu includes functional exercising of the video memory.
Code
Description
0900h
Video adapter
memory read or
write test failed

IDE CD-ROM

The IDE Tests include exercising of the CD-ROM tray response, data, and audio if present.
Code
Description
0A00h
No CD in drive.
0A01h
DiagTools Error
0A02h
DiagTools Error
0A03h
Sequential Data
Read Test Failed.
0A04h
Sequential Data
Test Failed. No CD
in Drive.
0A05h
Play test failed at
Recommended Action
Report error to HP Customer Care Center and get the latest version of DiagTools.
Report error to HP Customer Care Center and get the latest version of DiagTools.
Report error to HP Customer Care Center and get the latest version of DiagTools.
Report error to HP Customer Care Center and get the latest version of DiagTools.
Make sure the Speaker is properly connected. Run the test again. If it fails,
replace the drive. Replace the Speaker if it fails this test repeatedly.
Report error to HP Customer Care Center and get the latest version of DiagTools.
Report error to HP Customer Care Center and get the latest version of DiagTools.
Report error to HP Customer Care Center and get the latest version of DiagTools.
Report error to HP Customer Care Center and get the latest version of DiagTools.
Report error to HP Customer Care Center and get the latest version of DiagTools.
Report error to HP Customer Care Center and get the latest version of DiagTools.
Report error to HP Customer Care Center and get the latest version of DiagTools.
Recommended Action
1. Try another monitor. Rerun the test.
2. If the technical reference label or card on your NetServer shows a separate
video board, change it.
3. If the test still shows failing condition, change the system board.
Recommended Action
1. Insert a different data CD in the drive.
2. Check the cable between the CD and its controller.
3. Change the CD drive.
4. Change the board where the controller for the CD drive is located.
Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.
Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.
1. Insert a different data CD in the drive.
2. Check the cable between the CD and its controller.
3. Change the CD drive.
4. Change the board where the controller for the CD drive is located.
1. Insert a different data CD in the drive.
2. Check the cable between the CD and its controller.
3. Change the CD drive.
4. Change the board where the controller for the CD drive is located.
1. Insert a different data CD in the drive.
Error Message Reference