Chapter 5
Code
Description
0074h
CMOS RAM time is
invalid.
0075h
Time-base frequency
divider set at
incorrect value.
0076h
DiagTools Error
0077h
Periodic time update
cycle not occurring.
0078h
DiagTools Error
0079h
CMOS RAM fails to
hold data.
0080h
DiagTools Error
0081h
DiagTools Error
0082h
DiagTools Error
0083h
PCI System Bus
scan test failed.
34
Recommended Action
Run BIOS Setup if problem persists replace battery, if present. Then replace the
system board.
Reset the system and set BIOS Setup parameter. If the problem persists--replace
CMOS RAM and the battery.
Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.
1. Take ESD precautions and make sure the system board is seated.
2. Check the seating of the voltage regulator module (VRM) if present.
3. Be sure the processor board (if any) is seated.
4. Make sure the CPU chip is seated.
5. Make sure the memory elements (DIMMs) are properly seated.
6. Check system fans. If overheating occurs, chip may shut down.
7. If the system ran with temperature high, let it cool for 30 minutes, then restart.
8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.
Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.
1. Run the BIOS Setup program and reconfigure all settings.
2. If necessary, update the BIOS.
3. Clear the CMOS and rerun configuration. See directions on the technical
reference label or card.
4. Make sure the system board is seated.
5. Check the seating of the voltage regulator module (VRM) if present.
6. Be sure the processor board (if any) is seated.
7. Make sure the CPU chip is seated. (Take ESD precautions.)
8. Make sure the memory elements (DIMMs) are properly seated.
9. Check system fans. If overheating occurs, chip may shut down.
10. If the system ran with temperature high, let it cool for 30 minutes, then
restart.
11. If system repeatedly shows this error, replace the element with the CMOS.
Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.
Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.
Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.
1. Remove all unnecessary PCI cards and try the test again. If it still fails, make
sure all PCI connectors are seated.
2. Make sure the system board is seated.
3. Check the seating of the voltage regulator module (VRM) if present.
4. Be sure the processor board (if any) is seated.