HP D6030A - NetServer - E50 User Manual page 43

Error reference and user guide
Hide thumbs Also See for D6030A - NetServer - E50:
Table of Contents

Advertisement

Chapter 5
Code
Description
00A4h
NVRam base
address is invalid.
00A5h
PnP function 42
failed.
00A6h
PnP function 43
failed.
Recommended Action
6. Be sure the processor board (if any) is seated.
7. Make sure the CPU chip is seated. (Take ESD precautions.)
8. Make sure the memory elements (DIMMs) are properly seated.
9. Check system fans. If overheating occurs, chip may shut down.
10. If the system ran with temperature high, let it cool for 30 minutes, then
restart.
11. If system repeatedly shows this error, replace the element with the CMOS.
1. Run the BIOS Setup program and reconfigure all settings.
2. If necessary, update the BIOS.
3. Clear the CMOS and rerun configuration. See directions on the technical
reference label or card.
4. Make sure the system board is seated.
5. Check the seating of the voltage regulator module (VRM) if present.
6. Be sure the processor board (if any) is seated.
7. Make sure the CPU chip is seated. (Take ESD precautions.)
8. Make sure the memory elements (DIMMs) are properly seated.
9. Check system fans. If overheating occurs, chip may shut down.
10. If the system ran with temperature high, let it cool for 30 minutes, then
restart.
11. If system repeatedly shows this error, replace the element with the CMOS.
1. Run the BIOS Setup program and reconfigure all settings.
2. If necessary, update the BIOS.
3. Clear the CMOS and rerun configuration. See directions on the technical
reference label or card.
4. Make sure the system board is seated.
5. Check the seating of the voltage regulator module (VRM) if present.
6. Be sure the processor board (if any) is seated.
7. Make sure the CPU chip is seated. (Take ESD precautions.)
8. Make sure the memory elements (DIMMs) are properly seated.
9. Check system fans. If overheating occurs, chip may shut down.
10. If the system ran with temperature high, let it cool for 30 minutes, then
restart.
11. If system repeatedly shows this error, replace the element with the CMOS.
1. Run the BIOS Setup program and reconfigure all settings.
2. If necessary, update the BIOS.
3. Clear the CMOS and rerun configuration. See directions on the technical
reference label or card.
4. Make sure the system board is seated.
5. Check the seating of the voltage regulator module (VRM) if present.
6. Be sure the processor board (if any) is seated.
7. Make sure the CPU chip is seated. (Take ESD precautions.)
8. Make sure the memory elements (DIMMs) are properly seated.
9. Check system fans. If overheating occurs, chip may shut down.
10. If the system ran with temperature high, let it cool for 30 minutes, then
Error Message Reference
39