Cr_ Ptimer Command; Cr_Tempwarn Command - Sanyo PDG-DXL2000 - 2000 Lumens Specifications

Expand serial command functional specifications
Hide thumbs Also See for PDG-DXL2000 - 2000 Lumens:
Table of Contents

Advertisement

PDG-DXL2000 Expand Serial Command Functional Specifications

9.12.5 CR_ PTIMER Command

Command
"CR_ PTIMER"[CR]
Details
Get setting status of Presentation timer
Acceptable
Response
%a
Unacceptable

9.12.6 CR_TEMPWARN Command

Command
"CR_TEMPWARN"[CR]
Get the temperature inside a projector and its condition if it is abnormal
temperature or close to abnormal temperature
Details
If there are several sensors installed, it is possible to get information from all the
sensors at once.
Acceptable
%a
Response
%b
%c
Unacceptable
"000_%a"[CR]
"ON" ---------------------- Presentation timer is active
"STOP" ------------------- Presentation timer is pause
"OFF" --------------------- Presentation timer is inactive
"Error code"[CR]
"000_%a_%b_%c"[CR]
%a -------------------- Sensor 1 status
%b -------------------- Sensor 2 status
%c -------------------- Sensor 3 status
"W" ---- Approach or reach abnormal temperature
(dangerous temperature)
"S" ---- Far from abnormal temperature (safe temperature)
"N" ---- Sensor detects no abnormal temperature
[Example]
"S_W_S"[CR] means Sensor 1 detects safe temperature, Sensor
2 detects abnormal temperature and Sensor 3 detects safe
temperature
Note) When the temperature difference between Sensor 1 and 3
reaches specific value, some of the models detect it as Abnormal
temperature. In this case, the 3rd data shows if the temperature
difference between Sensor 1 and 3 is dangerous state or not. The
3rd data means temperature abnormality due to Sensor 3
When abnormal temperature is not detected by sensor, "N" (No
connection with temperature abnormality) is returned.
"Error code"[CR]
70/72

Advertisement

Table of Contents
loading