Cr_Pjlocknow Command; Cr_Pjlockmenu Command; Cr_Fanmode Command; Cr_Fancontrol Command - Sanyo PDG-DXL2000 - 2000 Lumens Specifications

Expand serial command functional specifications
Hide thumbs Also See for PDG-DXL2000 - 2000 Lumens:
Table of Contents

Advertisement

PDG-DXL2000 Expand Serial Command Functional Specifications

9.11.24 CR_PJLOCKNOW Command

Command
"CR_PJLOCKNOW" [CR]
Details
Get if PJ lock is actually in operation
Acceptable
Response
%1
Unacceptable

9.11.25 CR_PJLOCKMENU Command

Command
"CR_PJLOCKMENU" [CR]
Details
Get status of PJ Lock on Menu
Acceptable
Response
%1
Unacceptable

9.11.26 CR_FANMODE Command

Command
"CR_FANMODE"[CR]
Details
Get selected Fan mode
Acceptable
Response
%a
Unacceptable

9.11.27 CR_FANCONTROL Command

Command
"CR_FANCONTROL"[CR]
Details
Get selected Fan control setting status
Acceptable
Response
%a
Unacceptable

9.11.28 CR_FILH Command

Command
"CR_FILH"[CR]
Details
Get Filter used time
Acceptable
Response
%1
Unacceptable
"000_%1[CR]
"LOCK" ------------- PJ Lock is in operation. PJ Lock status is ON-1
or ON-2 on Menu, and PJ PIN CODE is not
entered so that projector is actually locked.
"FREE" ------------- PJ Lock is released. PJ Lock status is OFF, or,
status is ON-1 or ON-2 on Menu but PJ PIN
CODE is entered correctly so that PJ Lock is
released.
"Error Code" [CR]
"000_%1[CR]
"ON1" ------------- PJ Lock status is On-1
"ON2" ------------- PJ Lock status is On-2
"OFF" ------------- PJ Lock status is OFF
"Error Code" [CR]
"000_%a"[CR]
"L1" ----------------------- Fan mode is L1
"L2" ----------------------- Fan mode is L2
"Error code"[CR]
"000_%a"[CR]
"OFF" ----------------------- Fan control is OFF
"ON1" ----------------------- Fan control is ON1
"ON2" ----------------------- Fan control is ON2
"Error code"[CR]
"000_%1"[CR]
"00000"~"99999" ------------------- 0 hour to 99999 hours
"Error Code"[CR]
67/72

Advertisement

Table of Contents
loading