Dell PowerConnect 3424 User Manual page 97

Powerconnect 34 series
Hide thumbs Also See for PowerConnect 3424:
Table of Contents

Advertisement

Month — The month of the year in which DST begins every year. The possible field range is
Jan-Dec.
Time — The time at which DST begins every year. The field format is Hour: Minute, for
example, 02:10.
To — Defines the recurring time that DST ends each year. For example, DST ends locally every
fourth Friday in October at 5:00 am. The possible field values are:
Day — The day of the week at which DST ends every year. The possible field range is
Sunday-Saturday.
Week — The week within the month at which DST ends every year. The possible field range is 1-5.
Month — The month of the year in which DST ends every year. The possible field range is
Jan-Dec.
Time — The time at which DST ends every year. The field format is Hour:Minute, for
example, 05:30.
Selecting a Clock Source
1
Open the Time Synchronization page.
2
Define the Clock Source field.
3
Click Apply Changes.
The Clock source is selected, and the device is updated.
Defining Local Clock Settings
1
Open the Time Synchronization page.
2
Define the fields.
3
Click Apply Changes.
The local clock settings are applied.
Defining Clock Settings Using CLI Commands
The following table summarizes the equivalent CLI commands for setting fields displayed in the
Time Synchronization page.
NOTE:
The following steps must be completed before setting the summer clock:
1
Configure the summer time.
2
Define the time zone.
3
Set the clock.
Configuring System Information