Figure 6-5. Power Over Ethernet
The Power Over Ethernet page contains the following sections:
•
Global
•
Port Settings
Global
The Power over Ethernet Global Settings section contains the following fields:
Power Status — Indicates the inline power source status.
On — Indicates that the power supply unit is functioning.
Off — Indicates that the power supply unit is not functioning.
Faulty — Indicates that the power supply unit is functioning, but an error has occurred. For
example, a power overload or a short circuit.
Nominal Power — Indicates the actual amount of power the device can supply. The field value is
displayed in Watts.
Consumed Power — Indicates the amount of the power used by the device. The field value is
displayed in Watts.
System Usage Threshold (1-99 Percent) — Indicates the percentage of power consumed before an
alarm is generated. The field value is 1-99 percent. The default is 95 percent.
Traps — Enables or Disables receiving PoE device traps. The defaul