Power Supplies; Figure 2-10. Stacking Leds; Table 2-6. Stacking Led Indications - Dell PowerConnect 3424 User Manual

Powerconnect 34 series
Hide thumbs Also See for PowerConnect 3424:
Table of Contents

Advertisement

The Stacking LEDs indicate the unit position in the stack. The following figure illustrates the
LEDs on the front panel.

Figure 2-10. Stacking LEDs

The Stacking LEDs are numbered 1- 6. Each stacking unit has one stacking LED lit, indicating its
Unit ID number. If either Stacking LED 1 or 2 is lit, it indicates that the device is either the Stack
Master or Backup Master.

Table 2-6. Stacking LED Indications

LED
All Stacking LEDs
Stacking LED 1-6 (S1-S6)
Stacking Master LED

Power Supplies

The device has an internal power supply unit (AC unit) and a connector to connect PowerConnect
3424/P and PowerConnect 3448/P devices to a PowerConnect EPS-470 unit, or to connect
PowerConnect 3424 and PowerConnect 3448 devices to a PowerConnect RPS-600 unit. The
PowerConnect 3424/P and PowerConnect 3448/P devices have an internal power supply (12 Volt).
Operation with both power supply units is regulated through load sharing. Power supply LEDs
indicate the status of the power supply.
The PowerConnect 3424/P and PowerConnect 3448/P devices have an internal power supply of
470W (12V/-48V), with a total of 370W for 24 ports PoE device.
AC Power Supply Unit
The AC power supply unit operates from 90 to 264 VAC, 47 to 63 Hz. The AC power supply unit
uses a standard connector. LED indicator is on the front panel and indicates whether the AC unit
is connected.
Color
Description
OFF
The switch is currently a stand-alone device.
Green Static
The device is designated as Stacking Unit N.
OFF
The device is not designated as Stacking Unit N.
Green Static
The device is the Stack Master
OFF
The device is not the Stack Master.