3.8 To examine where to install the
virtual boundaries
CAUTION:
If the work area is adjacent
to water bodies, slopes, precipices or a
public road, there must be a protective wall.
The wall must be minimum 15 cm / 6 in. in
height.
CAUTION:
Do not let the product
operate on gravel.
For careful operation without noise, isolate all
obstacles such as trees, roots and stones.
Make a blueprint of the work area before you install
the virtual boundaries.
3.9 To install map objects near
buildings and trees
Make sure that 90° section of the sky is unimpeded
where the product operates.
90°
Note:
The product cannot receive signals from
the satellite for navigation if the sky is impeded.
Make a stay-out zone (B) around trees or a group
of trees with tree canopies that are more than 4 m /
13 ft. in diameter (A).
2211 - 002 - 30.11.2023
Note:
Trees or a group of trees with tree
canopies that are more than 4 m / 13 ft. in diameter
(A) can cause temporary stops for the product.
Smaller trees do usually not cause interference
with the operation of the product.
For L-shaped buildings, install the virtual boundary
at a minimum distance (C) of 1.5 m / 5 ft. from it.
C
To install virtual boundaries in an area with an U-
shaped building, make sure that the distance (E) is
minimum 6 m / 20 ft. If the building is higher than 3
m / 10 ft., make sure that the distance (E) is twice
the height of the highest building. Install the virtual
boundary at a minimum distance (D) of 1.5 m / 5 ft.
from the building.