ERROR CODE
ERROR CODE
FAULT ANALYSIS
E01
Poor signal
The motor wire is loose or
falling off, or check whether
E02
the carbon brush 1s worn
out
E03
No sensing signal
The controller or the
E04
motor is abnormal
E0S
Overload protection
Failed to self-check the
E06
system
The safety lock is not
E07
sucked
Abnormal
Outside interference
display
SPECIFICATIONS
Folded size
Unfolded Dimension
Running area
Motor Power
Speed range
Maximum load bearing capacity
Machine Weight
Controlling Mode
HANDLING METHOD AND SEQUENCE
The signal line is not plugged in
properly. Plug it in well.
Check whether the motor wire is loose
or falling off. If not, check whether the
carbon brush is worn out. If it is worn
out, replace the motor; If not, which
means the ECU is damaged, then
replace the EC.
The sensor cable is not plugged in
properly.
Overloaded, replace the controller
and the motor.
Overloaded, replace the electric
control
System fault, replace the electric
control.
Turn off the power supply, and power
on again after 1 minute
Turn off the power supply, and power
on again after 1 minute.
1346*691*125 mm
1292*691*948 mm
420*1080 mm
735W
1.0 -14Km/h
130 KG, 286LBS
39.6 KG, 87.3LBS
Console&Remote control
18
Need help?
Do you have a question about the STROL 3 and is the answer not in the manual?